LSS100300 SpaceLogic KNX BMS IP Gateway for EcoStruxure Building Automation Integration
Résumé du produit
Passerelle IP KNX-BACnet 3-en-1 avec certification BTL. Capacité de 4 000 objets pour une intégration transparente d’EcoStruxure. Réduit les coûts d’espace et d’installation dans l’automatisation des bâtiments commerciaux.
Propriétés de base
Lieu d'origine:
UE
Nom de marque:
Schneider
Certification:
CE RoHS
Numéro de modèle:
LSS100300
Propriétés commerciales
Quantité de commande minimale:
5
Conditions de paiement:
T/T, Union occidentale
Description de produit
SpaceLogic KNX BMS IP Gateway for EcoStruxure Building Automation
The LSS100300 SpaceLogic KNX BMS IP Gateway enables seamless integration between KNX TP bus systems and BACnet-based building management platforms, specifically designed for Schneider Electric's EcoStruxure Building Operation.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | LSS100300 |
| Type | 3-in-1 KNX BMS IP Gateway (KNX IP Router + KNX IP Interface + DPSU Choke) |
| Protocol | KNX TP ↔ BACnet IP (BACnet Protocol Revision 22) |
| BACnet Objects | 4,000 |
| BACnet COV Subscriptions | 4,000 |
| KNX Group Objects | 4,000 |
| KNX IP Routing Objects | 500 |
| Power Supply | DC 12 V - 30 V SELV (DPSU choke: DC 21 V - 31 V SELV) |
| Power Consumption | 2 W |
| Protection Rating | IP20 |
| Ambient Temperature | 0°C to +45°C |
| Dimensions | 4 modules (≈72 mm width) |
| Certification | BTL certified as BACnet Application Specific Controller (B-ASC) / B-GW |
Core Functions
- Bidirectional communication between KNX TP bus and BACnet systems
- Combined functionality as KNX IP router, KNX IP interface, and DPSU choke power supply
- Supports KNX IP tunneling, device commissioning, and long frame transmission
- Direct import of *.knxproj files with automatic filtering tables
- KNX IP Secure compatibility for enhanced network security
- Seamless integration with Schneider EcoStruxure Building Operation
Application Scenarios
- Commercial building automation systems (offices, hotels, retail spaces)
- Integration of KNX installations into EcoStruxure BMS platforms
- KNX lighting, HVAC, and room control systems with BACnet-based energy management
- Projects requiring seamless KNX-BACnet interoperability
- New construction and retrofitting of smart commercial buildings
Key Advantages
- 3-in-1 design reduces cabinet space requirements and installation costs
- BTL B-ASC certification ensures 100% BACnet compatibility
- High object capacity (4,000 BACnet/KNX objects) supports large-scale systems
- Streamlined configuration via direct *.knxproj file import
- Robust protection and wide operating temperature range for commercial environments
Détails de produit
Mettre en évidence:
KNX BMS IP Gateway for EcoStruxure
,DALI Gateway for building automation
,SpaceLogic KNX IP Gateway with warranty
Produits connexes
-
DCQC-150-SE Sensor Protection Cover with SE Logo for HVAC Sensors
Le couvercle du capteur DCQC-150-SE protège les capteurs CVC avec le logo SE. Offre une résistance à la poussière, une protection contre les chocs et une installation facile pour les capteurs de température, d'humidité et de qualité de l'air dans les conduits et les locaux techniques. -
HD5XMSTH Duct Mount Temperature Humidity Sensor for HVAC Building Automation
Le capteur à montage sur conduit VER-HD5XMSTH fournit une double mesure de température et d'humidité pour l'automatisation CVC. Garantit une haute précision, des performances stables et une installation facile dans les systèmes de ventilation pour une efficacité énergétique et un contrôle de la qualité de l'air améliorés. -
MTN683901 Schneider Alimentation de secours KNX pour automatisation de bâtiment
L'unité d'alimentation de secours Schneider KNX REG (MTN683901) garantit une alimentation ininterrompue du bus KNX avec une batterie de secours automatique. Monté sur rail DIN, certifié KNX et conçu pour une fiabilité 24h/24 et 7j/7 dans l'automatisation des bâtiments commerciaux et résidentiels.