Pengontrol VAV
SXWRPV4A10001 Schneider SpaceLogic RP-V-4A VAV Room Controller 4 Titik Berbasis IP dengan Damper Actu Terintegrasi
SXWRPV4A10001 Schneider SpaceLogic RP-V-4A VAV Room Controller 4-Point IP-Based with Integrated Damper Actu Product Overview The Schneider Electric SXWRPV4A10001 is a core component of the SpaceLogic EcoStruxure building management ecosystem, designed to provide high-performance RP-V Room Purpose ...
SXWCFV4A20001 Schneider Smart Field Pengontrol VAV Bus Lapangan 2UI 2DO
SXWCFV4A20001 Schneider Smart Field VAV Controller Field Bus 2UI 2DO The Schneider Electric SXWCFV4A20001 (Smart Field VAV Controller) is a fully programmable field-bus-based VAV controller for building automation systems in the EcoStruxure Building ecosystem. With 4 I/O points (2 universal inputs + ...
SXWMPV7AX10002 Schneider SpaceLogic MP-V-7A
SXWMPV7AX10002 Schneider SpaceLogic MP-V-7A BACnet IP MSTP VAV 7pt TAA The Schneider Electric SXWMPV7AX10002 (SpaceLogic MP-V-7A) is a multi-purpose, fully programmable VAV field controller supporting both BACnet/IP and BACnet MS/TP (MSTP) communication protocols simultaneously — critical for ...
SXWMPV9AX10002 Schneider SpaceLogic MP-V-9A
SXWMPV9AX10002 Schneider SpaceLogic MP-V-9A BACnet IP MSTP VAV 9pt TAA The Schneider Electric SXWMPV9AX10002 (SpaceLogic MP-V-9A) is the flagship VAV field controller in the SpaceLogic MP-V series, offering the highest I/O count: 4 universal inputs, 3 digital Triac outputs, and 2 analog outputs ...
SXWRPV4A10001 Schneider SpaceLogic RP-V-4A BACnet/IP Pengontrol VAV TAA
SXWRPV4A10001 Schneider SpaceLogic RP-V-4A BACnet/IP VAV Controller TAA The Schneider Electric SXWRPV4A10001 (SpaceLogic RP-V-4A) is a fully programmable, BACnet/IP-native field controller purpose-built for Variable Air Volume (VAV) HVAC applications. It integrates 4 universal I/O points, a built-in ...
SXWRPV5A10001 Schneider SpaceLogic RP-V-5A Pengontrol BACnet/IP VAV 5pt
SXWRPV5A10001 Schneider SpaceLogic RP-V-5A BACnet/IP VAV Controller 5pt The Schneider Electric SXWRPV5A10001 (SpaceLogic RP-V-5A) is the five-point variant of the SpaceLogic RP-V VAV controller family. It adds 2 universal inputs and 3 digital/relay outputs over the RP-V-4A, making it suitable for ...
MN-S1-500 Schneider MicroNet VAV Sensor Suhu Kamar Tanpa Penutup
MN-S1-500 Schneider MicroNet VAV Room Temperature Sensor No Cover The Schneider Electric MN-S1-500 is a wall-mounted digital room temperature sensor engineered for Variable Air Volume (VAV) HVAC zone monitoring in commercial and light industrial buildings. As a sensor-only device with no occupant...
MNB-V2-2 Schneider MN VAV BACnet Pengontrol Otomatisasi Bangunan Baru
MNB-V2-2 Schneider MN VAV BACnet Controller Building Automation The Schneider Electric MN VAV BACnet Controller MNB-V2-2 is a BACnet MS/TP-compliant heating/cooling VAV terminal unit controller, adding reheat or dual-duct control capability to the BACnet-open VAV platform for perimeter zones ...
Pengontrol VAV BACnet MN-V2-2 untuk Sistem Kontrol Volume Udara Variabel
MNB-V2-2 BACnet VAV Controller menawarkan kontrol volume & suhu udara yang presisi dengan integrasi BMS asli. Desain ringkas dan hemat energi ideal untuk sistem HVAC komersial di kantor, rumah sakit, dan gedung pintar.