ABOUT Maituo Intelligent Technology Co.,Ltd
Switch Actuator & Dimming Actuator Manufacturer
-
12-channel KNX switch actuator for 230V/16A mid-load control. Features sequential start/stop, overload protection, and manual emergency mode. Ideal for large commercial buildings requiring reliable cluster control of lighting, HVAC, and equipment.
-
Schneider KNX Basic Logic Module: DIN-rail mounted, KNX-certified. Executes AND/OR/NOT logic, timers & scenes. Compact, cost-effective automation for lighting, blinds & HVAC.
-
ABB SD/S 2.16.1: 2-channel KNX dimming actuator with 16A capacity per channel. DIN-rail mounted for easy installation, compatible with various lighting loads. CE & KNX certified, features manual override and robust protection for reliable smart building automation.
-
Schneider KNX DALI Gateway connects KNX building systems with DALI lighting. Controls 64 devices, 16 groups & scenes. DIN rail mount, 240V. Ideal for commercial, hotel & industrial automation.
-
Schneider spaceLYnk LSS100200: Multi-protocol gateway for KNX, Modbus & BACnet. Enables cross-system device integration with 500+ custom logic commands, DIN rail mounting, and remote web management for smart building automation.
-
Schneider KNX presence detector with dual PIR/ultrasonic tech for reliable occupancy detection. Features 2 digital inputs for sensor expansion, KNX integration, and adjustable settings. Reduces energy costs by 20-35% while preventing false triggers in offices, hotels, and retail spaces.
-
5WG1286-2DB13 KNX Pushbutton Double With Status LED Titanium White DELTA Style UP 286/13 Product Overview The 5WG1286-2DB13 (UP 286/13) provides two-channel KNX pushbutton control in the DELTA style with integrated status LEDs on both rocker pairs. The LEDs display the current state of each ...
-
ABB's 6320/30-500 KNX Triton 6-gang control unit combines switching, dimming, blind control & IR remote in one device. Integrated KNX bus coupler eliminates external hardware, ensuring industrial durability, energy efficiency & seamless BMS integration for luxury residential/commercial applications.
100% brand-new and original components direct from the manufacturer. Safeguards your project's stability, safety, and long-term reliable operation.
Rapid response within 1–2 working hours. Drives smoother collaboration and effectively reduces potential delays for your industrial project.
Fast delivery via DHL, UPS, and FedEx. Tailored to time-sensitive logistics needs, directly boosting your project's on-site progress.
Targeted technical support for electrical needs. Includes professional selection/design and KNX assembly to streamline your project implementation.
Many technicians finish installing KNX modules on-site, but get stuck when opening the ETS software. Actually, ETS follows a clear workflow. Just follow these 5 steps, and you can get started with ease. Step 1: Create a new project & set up bus topology Launch ETS → Create a new project → Select KNX ...
Many clients ask: "KNX systems can dim lights, but how is this different from regular dimmers?" The difference is huge—they operate on completely different fundamental logic. Core Principle of KNX Dimming KNX dimming controls dimming actuators by sending brightness values over the bus. Sensors ...
Frequent KNX communication dropout months after commissioning? Before replacing faulty modules, check field wiring against below five specifications for quick troubleshooting. Only adopt dedicated KNX twisted pair cable Standard colour coding: Red(+), Black(-), Yellow&White(data), 0.8mm² conductor. ...
Quick Overview A KNX IP controller acts as a communication bridge between the KNX fieldbus and Ethernet network. Without this device, KNX devices can only communicate within the local bus. With it, mobile APPs, building management systems and remote maintenance platforms are able to monitor and ...
Improper selection of KNX blind actuators will cause inaccurate movement or even motor burnout. Confirm the following three key points before purchasing. 1. Confirm Blind Type First Curtain (side-opening): Use dedicated curtain actuators to control motor forward/reverse rotation. Travel is set by ...
Why a Wrong Power Supply Causes Issues All devices on a single KNX bus are powered centrally by the bus power supply. Undersized power supply: Frequent device disconnections & failed program uploads. Oversized power supply: Unnecessary cost with no practical benefits. 320mA vs 640mA: How to Choose ...
-
After comparing several suppliers, we ultimately chose Maite. It turns out our choice was correct; their products offer excellent value for money while still meeting all certification standards. The shipment was on time and the packaging was professional, resulting in no transport damage whatsoever. We look forward to our next bulk purchase .
-
Our plant requires frequent washdowns, so standard electrical enclosures just won't last. Maite provided us with stainless steel cabinets that are corrosion-resistant and easy to clean. The quality is top-tier, and the delivery was right on schedule despite our tight timeline.
-
For our new hotel branch, we needed a KNX solution that could handle complex room controls. Maite customized the DDC cabinets to fit our specific hotel management protocols. The feedback from our guests regarding the room temperature and lighting control has been excellent. Great quality, fast delivery, and they speak the language of KNX fluently.
-
It's a pleasure working with such a reliable partner like Maituo Intelligent Technology Co., Ltd.. Here’s to more smooth cooperation and shared success in the future.
-
Nora is extremely friendly with prompt responses, they offer competitive pricing, ensure on-time delivery and provide 100% genuine original products. We will definitely place repeat orders!
-
Schneider KNX Dimming Modules: Intelligent Lighting Case Study for Commercial ComplexesProject Background East China International Financial Center (420,000 m², including office buildings, shopping malls, and hotels) faced three major challenges with its lighting system: Complex multi-format scenario requirements that traditional controls could not meet Lighting energy consumption ...
read more -
Haige Tianshu Refrigeration Plant Project: Core Applications and Value Empowerment of KNX SystemIn the Haige Tianshu Refrigeration Plant Project, the KNX system—an internationally recognized standard for intelligent building control buses—serves as the "central nervous system" for the automated operation of the refrigeration plant. With "centralized management, distributed linkage, and precise ...
read more -
Local-Remote Balance + Microgrid Integration: SpaceLogic KNX Drives Green E-Commerce OperationAs a core hub for cross-border trade in the Yangtze River Delta, Pinghu Cross-Border E-Commerce Park covers intelligent warehousing, sorting centers, office clusters, and supporting service areas. Its core demands focus on efficient energy management across the entire park, quantitative achievement ...
read more -
Elevating Luxury Hotel Experience: KNX Solution with DALI-KNX & IoT in Poly Yueya HotelSanya Poly Yueya Hotel, as a high-end resort destination, needs to balance guest comfort experience, operational energy consumption control, intelligent service quality, and sustainable development goals. As a globally universal intelligent building control bus standard, the KNX system, based on its ...
read more -
mmWave Sensing & AI-Predictive Maintenance: ABB KNX in Central China Children's HospitalAs a key medical institution focusing on children's health, Central China Children's Hospital needs to balance medical service efficiency, children's safety protection, comfort of medical environment, and green operation goals. In 2026, the KNX system, driven by AI automation technology, has ...
read more
Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.