KNX System: Diagram of Common Modules & Functions
When you first open a KNX control cabinet, many people do not ask what smart functions it can achieve. Instead, they wonder: What does each module in this row do?
The core logic is easy to remember: Sensors perceive the environment and send commands; actuators receive commands and drive equipment. Bus power supplies, couplers and IP devices handle power supply, line isolation and network communication.
1.Sensors / Push-button Panels Signal input sources. Wall-mounted push panels, thermostats, presence sensors and daylight sensors are all input devices. They convert button operations, occupancy detection, temperature and light changes into KNX bus signals. Panels do not cut mains power directly — they only send signals. Final equipment actions are determined by actuators and logic.
2.Switching & Dimming Actuators Lighting controllers. Switch actuators turn circuits on and off; dimming actuators adjust light brightness. They are mostly installed inside distribution boxes. The channel count equals the number of controllable outputs. Loads cannot be connected arbitrarily. Verify the rated current, load type and dimming protocol for product selection.

3.Shutter / Blind Actuators For shading motors. Designed for roller blinds, venetian blinds and electric curtains. They support lifting, stopping, position control and slat angle adjustment. Wiring, motor interlock and travel limit settings must be configured strictly according to the project plan and product manual.
4.Heating / Valve Actuators Core for temperature control. Thermostats collect temperature data and send control requests. Valve or fan-coil actuators act based on preset logic. Multiple control modes are available, such as on-off and PWM. Different models are not interchangeable.

5.KNX Bus Power Supply Bus power source. It supplies voltage for the KNX twisted-pair bus, and does not power lighting or other loads. Capacity cannot be simply estimated by the number of modules. Calculate bus current and zoning, and reserve design margin.
6.Couplers & IP Interfaces Line and network communication. Line couplers connect different KNX lines or zones, supporting telegram filtering and fault isolation. IP interfaces are used for ETS commissioning and network access. IP routers additionally support KNXnet/IP cross-area routing; these two devices have different functions.

Two common expansion modules Binary input modules: Connect dry contacts and external switch signals, ideal for renovation projects and integration with third-party non-KNX devices. Logic / Visualization modules: Enable scenes, timers and conditional linkage. Work with touch panels or host systems for status visualization.
KNX workflow recap: Push buttons / sensors capture signals → KNX bus transmits telegrams → various actuators drive lights, curtains and valves. Bus power supply feeds the bus; couplers provide zoning and isolation; IP devices enable networking and commissioning.