AE/S 4.1.1.3 ABB 4-Fold Analogue Input Module KNX PT100/PT1000 MDRC Enabled

Product Summary
ABB AE/S 4.1.1.3 KNX 4-channel analog input module with MDRC. Supports PT100/PT1000, voltage, current & resistance signals. Dual power supply, 24V sensor power, DIN-rail mount. CE & KNX BTL certified for building automation.
Basic Properties
Place of Origin: EU
Brand Name: ABB
Certification: CE Rohs
Model Number: AE/S 4.1.1.3
Trading Properties
Minimum Order Quantity: 1
Payment Terms: T/T,Western Union
Product Description
ABB AE/S 4.1.1.3 4-Fold Analogue Input Module KNX PT100/PT1000 MDRC Enabled
The ABB AE/S 4.1.1.3 is a 4-channel analogue input module for the ABB i-bus® KNX smart building control system with MDRC functionality. This high-precision module collects, converts, and processes multiple analog signal types, supporting connection with four commercial sensors. It captures diverse signals including voltage, current, resistance, PT100/PT1000 temperature signals, and floating contacts, while integrating a 24V DC power supply for external sensors.
Technical Specifications
Model Number AE/S 4.1.1.3 (2CDG110190R0011)
Product Type ABB i-bus® KNX 4-fold analogue input module (MDRC-enabled)
Channel Quantity 4 independent analogue input channels
Signal Types Voltage: 0-1V/0-5V/0-10V/1-10V DC (max 12V); Current: 0-20mA/4-20mA DC (max 25mA); Resistance: 0-1000Ω; PT100/PT1000 (2/3-conductor); Floating contacts
Power Supply Bus voltage: 21-32V DC; Mains voltage: 85-265V AC/110-240V DC (50/60Hz)
Sensor Power Supply Integrated 24V DC auxiliary power, rated current 300mA
Power Consumption Max 11W (230V AC); Device power loss max 3W (230V AC)
Current Consumption Bus: <10mA; Mains: 80mA(115V AC)/40mA(230V AC)
Connection Mode KNX bus: screwless terminal; Mains/sensor: screw terminals
Terminal Specification 0.2-2.5mm² fine stranded wire; 0.2-4.0mm² single core wire; Max tightening torque 0.6Nm
Maximum Cable Length 100m (between sensor and device input)
Programming & Operation ETS software parameterization/programming; Physical address assignment via button/LED
Protection Standard IP20; Protection Class II; Overvoltage Category III; Pollution Degree II
Installation Type DIN-rail mounted (35mm, 4×18mm modules), net width 72mm
Dimensions (H×W×D) 90mm × 72mm × 64.5mm
Net Weight 0.23kg (gross weight 0.27kg)
Operating Temperature -5°C to +45°C (max humidity 93%, no condensation)
Storage/Transport Temp. Storage: -25°C to +55°C; Transport: -25°C to +70°C
Housing Gray flame-retardant plastic, modular installation design
Certifications CE, KNX BTL certified (EN 50090-1/2); RoHS compliant
Applications
Commercial Building Multi-Parameter Monitoring
Applied in office towers, shopping malls and hotels to connect temperature, humidity, CO₂, air pressure and brightness sensors for simultaneous collection of multiple environmental parameters. Transmits real-time data to KNX BMS to realize intelligent linkage control of HVAC, ventilation and lighting systems, optimizing indoor comfort and energy efficiency.
Industrial Energy Consumption & Equipment Sensing
Used in industrial parks, production workshops and logistics warehouses to connect energy meters, current/voltage transducers and liquid level/pressure sensors. Collects analog signals of electricity/water/gas consumption and equipment operating parameters, supporting energy consumption statistics, equipment status monitoring and abnormal alarm.
HVAC System Closed-Loop Control
Matched with central air conditioning, fan coil and water supply systems in large buildings. Collects pipeline temperature (PT100/PT1000), water pressure and air supply flow analog signals to realize closed-loop intelligent regulation of HVAC equipment, improving operation efficiency and reducing energy consumption.
Public Building Environmental & Safety Sensing
Installed in schools, hospitals, government buildings and metro stations to collect analog signals of indoor temperature, humidity, air quality and fire-fighting system pressure. Provides data support for public building environmental control and safety early warning, complying with public facility operation standards.
Mixed-Use Development Integrated Sensing
Serves as the analog signal acquisition core for KNX systems in mixed-use towers and residential communities. Realizes unified collection and transmission of environmental parameters, energy consumption data and public facility operating signals of commercial areas, residential areas and public areas, supporting centralized management and intelligent scheduling of the whole community.
Smart Industrial Auxiliary Monitoring
Applied in light industrial production lines to connect speed, weight, temperature and position sensors. Collects analog signals of production equipment and product processing parameters, transmits data to the KNX system for auxiliary monitoring of production processes, and supports simple linkage control of supporting equipment.
Product Details
Highlight:

ABB KNX PT100 input module

,

4-fold analogue input module

,

KNX PT1000 MDRC module

Input Current: Analog (0 ... 10 V / 4 ... 20 MA) 4
Product Or Component Type: ABB 2CDG110086R0011
Mountingtype: DIN Rail
Operatingtemperature: -20°C To 60°C
Number Of Inputs: 2
Material: Plastic
Color: Light Grey
IP Rating: IP20
Dimension: 72*90*65mm