MNB-V2-2 Schneider MN VAV BACnet Controller Building Automation New

Product Summary
MNB-V2-2 Schneider MN VAV BACnet Controller Building Automation The Schneider Electric MN VAV BACnet Controller MNB-V2-2 is a BACnet MS/TP-compliant heating/cooling VAV terminal unit controller, adding reheat or dual-duct control capability to the BACnet-open VAV platform for perimeter zones ...
Basic Properties
Place of Origin: EU
Brand Name: Schneider
Certification: CE RoHS
Model Number: MNB-V2-2
Trading Properties
Minimum Order Quantity: 5
Payment Terms: T/T,Western Union
Product Description
MNB-V2-2 Schneider MN VAV BACnet Controller Building Automation
The Schneider Electric MN VAV BACnet Controller MNB-V2-2 is a BACnet MS/TP-compliant heating/cooling VAV terminal unit controller, adding reheat or dual-duct control capability to the BACnet-open VAV platform for perimeter zones requiring both cooling and supplementary heating.
Key Specifications
Part Number MNB-V2-2
Protocol BACnet MS/TP (ASHRAE 135)
Control Mode Cooling + heating (reheat or dual-duct)
Outputs Damper (0-10V) + reheat output (analogue or digital)
Room Sensor Compatible MN-S series
Power Supply 24 VAC
Compatibility Any BACnet MS/TP supervisor
Applications
Used on perimeter VAV zones in BACnet-specified commercial buildings. Controls primary air damper for cooling and activates reheat when space temperature falls below heating setpoint — the standard perimeter zone VAV control sequence. BACnet MS/TP protocol gives facility managers vendor-independent supervisor access, enabling long-term system flexibility as building management platforms evolve.
Brand new, original Schneider Electric product.
Product Details
Highlight:

Schneider MN VAV BACnet Controller

,

Building Automation VAV BACnet Controller

,

MN VAV BACnet Controller

Sensor Compatibility: Temperature, Pressure, Humidity Sensors
Adjustable Parameters: Setpoint Temperature, Airflow Setpoint
Control Method: Modulating Control
Type: Variable Air Volume Controller
Dimensions: Varies By Model, Typically Compact Size
Mounting Type: DIN Rail Or Panel Mount

Ms. Nora

Sales Manager

Related Products
  • SXWRPV4A10001 Schneider SpaceLogic RP-V-4A BACnet/IP VAV Controller TAA

    SXWRPV4A10001 Schneider SpaceLogic RP-V-4A BACnet/IP VAV Controller TAA The Schneider Electric SXWRPV4A10001 (SpaceLogic RP-V-4A) is a fully programmable, BACnet/IP-native field controller purpose-built for Variable Air Volume (VAV) HVAC applications. It integrates 4 universal I/O points, a built-in ...
  • MNB-V2-2 Schneider MN VAV BACnet Controller Building Automation New

    MNB-V2-2 Schneider MN VAV BACnet Controller Building Automation The Schneider Electric MN VAV BACnet Controller MNB-V2-2 is a BACnet MS/TP-compliant heating/cooling VAV terminal unit controller, adding reheat or dual-duct control capability to the BACnet-open VAV platform for perimeter zones ...
  • SXWASB24X10001 SCHNEIDER SMARTX AS-B-24 BUILDING CONTROLLER NO DISPLAY NEW

    SXWASB24X10001 SCHNEIDER SMARTX AS-B-24 BUILDING CONTROLLER NO DISPLAY NEW The Schneider Electric SmartX AS-B-24 Building Controller (Part No. SXWASB24X10001) is a 24-point BACnet/IP and MS/TP programmable field controller without display, designed for EcoStruxure Building Operation deployments in ...
Send An Inquiry