MN-S3HT-500 Schneider MicroNet Temp Humidity Sensor LCD Setpoint Override
| Part Number | MN-S3HT-500 |
| Temperature Sensor | Precision Thermistor |
| Humidity Sensor | Thermoset Polymer Capacitive element |
| Communication Protocol | S-Link (proprietary MicroNet bus — power + data combined) |
| Power Supply | Bus-powered via S-Link |
| Temperature Sensing Range | 32 to 122°F (0 to 50°C) |
| Temperature Accuracy | ±2% |
| Humidity Sensing Range | 5% to 95% RH, non-condensing |
| Humidity Hysteresis | ±1.2% RH maximum |
| Display | Large LCD — temperature + humidity simultaneously |
| Keypad | 3-button interface |
| System Modes | Heat / Cool / Off / Auto |
| Fan Modes | Off / On / Low / Medium / High / Auto |
| Enclosure Rating | NEMA-1 |
| Dimensions | 4.5 x 2.8 x 1.0 in. (114 x 71 x 25 mm) |
| Mounting | Direct wall / 2x4 box / 1/4 DIN box / surface box |
| Cover | Not included — DCQC-150-SE sold separately |
| Certifications | UL, cUL, CE, CSA, FCC Part 15 Class B |
| Compatible Software | EcoStruxure Building Operation |
- Dual-sensing capability for temperature and humidity monitoring
- Superior thermoset polymer capacitive humidity sensor for long-term stability
- Simultaneous LCD display of both parameters
- Three-button interface for setpoint adjustment and override
- S-Link bus communication for power and data transmission
- Multiple mounting options for flexible installation
Healthcare facilities use the MN-S3HT-500 to monitor infection-control-critical zone humidity levels alongside temperature.
Archival storage rooms and museums deploy it to protect documents and artifacts from humidity excursions.
Data center perimeter zones rely on the thermoset capacitive element for stable long-term RH readings.
In LEED-certified buildings, dual-parameter monitoring contributes to indoor environmental quality documentation requirements.
Schneider MicroNet temperature humidity sensor
,LCD setpoint override room sensor
,Schneider MicroNet sensor with LCD
-
9141047000 Schneider RM4 Voltage Control Relay 3-Phase Base Professional Industrial HVAC Automation Module
9141047000 Schneider RM4 Voltage Control Relay 3-Phase Base Professional Industrial HVAC Automation Module Product Overview The Schneider Electric 9141047000 is a high-specification RM4 Voltage Control Relay 3-Phase Base from the prestigious Zelio RM4 series, engineered to deliver exceptional ... -
8740003000 Schneider Damper Actuator LF24 Spring Return Modulating Professional Industrial HVAC Automation Module
8740003000 Schneider Damper Actuator LF24 Spring Return Modulating Professional Industrial HVAC Automation Module Product Overview The Schneider Electric 8740003000 is a high-specification Damper Actuator LF24 Spring Return Modulating from the prestigious LF24 series, engineered to deliver ... -
SLPBXC2 Schneider SLP IAQ Sensor Blank Black Professional Intelligent Building Automation Protocol Sensor
SLPBXC2 Schneider SLP IAQ Sensor Blank Black Professional Intelligent Building Automation Protocol Sensor Product Overview The Schneider Electric SLPBXC2 is a professional-grade SLP IAQ Sensor Blank Black from the premium SpaceLogic SLP series, engineered for high-performance integration within ...