MN-S3HT-500 Schneider MicroNet Temp Humidity Sensor LCD Setpoint Override
| Part Number | MN-S3HT-500 |
| Temperature Sensor | Precision Thermistor |
| Humidity Sensor | Thermoset Polymer Capacitive element |
| Communication Protocol | S-Link (proprietary MicroNet bus — power + data combined) |
| Power Supply | Bus-powered via S-Link |
| Temperature Sensing Range | 32 to 122°F (0 to 50°C) |
| Temperature Accuracy | ±2% |
| Humidity Sensing Range | 5% to 95% RH, non-condensing |
| Humidity Hysteresis | ±1.2% RH maximum |
| Display | Large LCD — temperature + humidity simultaneously |
| Keypad | 3-button interface |
| System Modes | Heat / Cool / Off / Auto |
| Fan Modes | Off / On / Low / Medium / High / Auto |
| Enclosure Rating | NEMA-1 |
| Dimensions | 4.5 x 2.8 x 1.0 in. (114 x 71 x 25 mm) |
| Mounting | Direct wall / 2x4 box / 1/4 DIN box / surface box |
| Cover | Not included — DCQC-150-SE sold separately |
| Certifications | UL, cUL, CE, CSA, FCC Part 15 Class B |
| Compatible Software | EcoStruxure Building Operation |
- Dual-sensing capability for temperature and humidity monitoring
- Superior thermoset polymer capacitive humidity sensor for long-term stability
- Simultaneous LCD display of both parameters
- Three-button interface for setpoint adjustment and override
- S-Link bus communication for power and data transmission
- Multiple mounting options for flexible installation
Healthcare facilities use the MN-S3HT-500 to monitor infection-control-critical zone humidity levels alongside temperature.
Archival storage rooms and museums deploy it to protect documents and artifacts from humidity excursions.
Data center perimeter zones rely on the thermoset capacitive element for stable long-term RH readings.
In LEED-certified buildings, dual-parameter monitoring contributes to indoor environmental quality documentation requirements.
-
N 526E02 KNX Switch Dim Actuator 8x AC 230V 16A 1-10V DIN Rail Relay UL Standard 5WG1526-1EB02
N 526E02 KNX Switch Dim Actuator 8x AC 230V 16A 1-10V DIN Rail Relay UL Standard 5WG1526-1EB02 This KNX switch/dimming actuator controls eight independent lighting channels for AC 230 V, 50/60 Hz applications and is UL standard certified. Each channel provides a 16 A relay switching output at power ... -
N 263D51 KNX Binary Input Module 8xAC/DC 10-230V, DIN Rail LED Status Display 5WG1263-1DB51
N 263D51 KNX Binary Input Module 8xAC/DC 10-230V, DIN Rail LED Status Display 5WG1263-1DB51 The KNX binary input module delivers eight voltage inputs across AC/DC 10 to 230 V, allowing direct connection of active sensors, relay contacts, and signal sources. Each input is equipped with a direct ... -
N 262D51 KNX Binary Input Module 8x Dry Contacts DIN Rail LED Status Display 5WG1262-1DB51
N 262D51 KNX Binary Input Module 8x Dry Contacts DIN Rail LED Status Display 5WG1262-1DB51 The KNX binary input module provides eight dry contact inputs for reading potential-free contacts in building automation installations. Each input features a direct operation function with LED status ...