SXWMPV7AX10002 Schneider SpaceLogic MP-V-7A BACnet IP MSTP VAV 7pt TAA

Product Summary
SXWMPV7AX10002 Schneider SpaceLogic MP-V-7A BACnet IP MSTP VAV 7pt TAA The Schneider Electric SXWMPV7AX10002 (SpaceLogic MP-V-7A) is a multi-purpose, fully programmable VAV field controller supporting both BACnet/IP and BACnet MS/TP (MSTP) communication protocols simultaneously — critical for ...
Basic Properties
Place of Origin: EU
Brand Name: Schneider
Certification: CE RoHS
Model Number: SXWMPV7AX10002
Trading Properties
Minimum Order Quantity: 5
Payment Terms: T/T,Western Union
Product Description
SXWMPV7AX10002 Schneider SpaceLogic MP-V-7A BACnet IP MSTP VAV 7pt TAA
The Schneider Electric SXWMPV7AX10002 (SpaceLogic MP-V-7A) is a multi-purpose, fully programmable VAV field controller supporting both BACnet/IP and BACnet MS/TP (MSTP) communication protocols simultaneously — critical for buildings with mixed-protocol BAS infrastructure. With 7 I/O points (3 universal inputs, 3 digital Triac outputs, 1 analog output), the MP-V-7A covers the majority of mid-complexity VAV zone configurations. Integrated 10 N.m damper actuator, factory-calibrated airflow sensor, dual-port Ethernet switch, BACnet/Secure Connect (BACnet/SC) cybersecurity support. TAA compliant.
Technical Specifications
Part Number SXWMPV7AX10002
Model SpaceLogic MP-V-7A
Communication Protocols BACnet/IP AND BACnet MS/TP (MSTP) — simultaneously
Network Interface Dual-port Ethernet switch
Total I/O Points 7
Universal Inputs (UI) 3 (temperature, humidity, CO2, occupancy, pressure sensors)
Digital Triac Outputs (DO) 3 (24 V Triac — fan, reheat stage, auxiliary)
Analog Outputs (AO) 1 (0-10 V modulating valve or actuator)
Integrated Actuator Yes — 10 N.m damper actuator
Integrated Airflow Sensor Yes — differential pressure, factory-calibrated
Power Supply Voltage 24 V AC +/-20%
Operating Temperature 32 to 122°F (0 to 50°C)
Dimensions 7.8 x 6.3 x 2.5 in. (198 x 161 x 63 mm)
Secure Communications BACnet/Secure Connect (BACnet/SC)
Certifications UL 916, UL 2043 Plenum, CE, RCM, ICES-003, EN 61000-6-2/3, FCC Part 15 Subpart B
Compatible Software EcoStruxure Building Operation (EBO) v4.0+, EcoStruxure Building Commissioning App
TAA Compliant Yes
Applications
  • The SXWMPV7AX10002 is the practical choice for mid-complexity commercial VAV zones
  • In retail shopping centers, 3 universal inputs simultaneously support room temperature, CO2, and duct temperature monitoring
  • In mixed-protocol school BAS systems, simultaneous BACnet/IP + MSTP enables integration into both legacy MSTP trunks and new IP backbone networks without gateways
  • BACnet/SC meets enterprise cybersecurity mandates
Product Details
CommunicationProtocol: BACnet MS/TP
ControlType: Variable Air Volume
Compatibility: HVAC Systems
ActuatorType: Modulating Damper Actuator
MountingType: DIN Rail Or Panel Mount
SensorType: Temperature And Pressure Sensors
OutputType: Analog And Digital Outputs

Ms. Nora

Sales Manager

Related Products
  • MN-S4-500 Schneider MicroNet VAV Sensor Setpoint Override Controller Mode

    MN-S4-500 Schneider MicroNet VAV Sensor Setpoint Override Controller Mode The Schneider Electric MN-S4-500 is the direct replacement for the legacy MN-S4 MicroNet sensor, adding full Controller Mode Functions to the setpoint and override capabilities of the MN-S3-500. In addition to temperature ...
  • DCQC-150-SE Schneider Sensor Cover SE Logo Brand New Original

    DCQC-150-SE Schneider Sensor Cover SE Logo Brand New Original Product Overview The Schneider Electric Sensor Cover DCQC-150-SE (Part No. DCQC-150-SE) is a branded replacement cover for Schneider Electric (SE) branded room sensors. This cover provides a clean, consistent aesthetic finish in ...
  • SXWASPXXX10002 Schneider Network Control Server AS-P-NL Brand New

    SXWASPXXX10002 Schneider Network Control Server AS-P-NL The Schneider Electric Network Control Server AS-P-NL (Part No. SXWASPXXX10002) is the supervisory-level server for SmartX EcoStruxure Building Operation deployments, providing real-time data aggregation, alarm management, trend logging, ...
Send An Inquiry