SE8350U5B11 Schneider SpaceLogic SE8000 Fan Coil Controller PIR White
| Parameter | Value |
|---|---|
| Part Number | SE8350U5B11 |
| Series | SpaceLogic SE8000 Room Controller |
| Communication Protocols | BACnet MS/TP, Modbus RTU |
| Display | Colored capacitive touchscreen, multi-language support |
| Fascia Color | White |
| PIR Motion Sensor | Yes — integrated occupancy detection |
| Digital Inputs (DI) | 2 |
| Analog Inputs (AI) | 5 (5–10 V DC) |
| Analog Outputs (AO) | 4 (0–10 V DC) |
| Digital Outputs (DO) | 5 |
| Total I/O Points | 16 |
| Integrated RH Sensor | Yes — with dehumidification control |
| Supply Voltage | 24 V AC |
| Relay Output | 24 V AC |
| Setpoint Range | 12–37.5°C cooling / 4.5–32°C heating |
| Wireless Connectivity | Yes — supports wired and wireless protocols |
| Mounting | Wall-mounted |
| Standards | BACnet BTL Listed, CE, UL |
| Total Lifecycle Carbon Footprint | 180 kg CO2 eq. |
| Packaging | Min. 70% recycled cardboard |
| Stock Status | Normally stocked in distribution |
- Integrated PIR motion sensor for occupancy detection
- Automatic HVAC setpoint adjustment between occupied/unoccupied modes
- Colored capacitive touchscreen with multi-language support
- BACnet MS/TP and Modbus RTU communication protocols
- 16 configurable I/O points for flexible integration
- Integrated relative humidity sensor with dehumidification control
- Energy-efficient operation for reduced consumption
The SE8350U5B11 is specified in LEED and BREEAM certified projects where occupancy-based HVAC control contributes directly to energy efficiency credits. In hotel guest rooms, the PIR sensor enables automatic setback to energy-saving mode when guests leave — a common requirement in international hotel operator brand standards (Marriott, Hilton, IHG). In healthcare, automatic unoccupied setback in patient rooms reduces energy waste during periods when clinical staff are attending to other areas. The controller's self-configuring PIR integration requires no additional wiring or BMS programming, making it the preferred solution for contractors seeking to minimize commissioning complexity while delivering energy-efficient, code-compliant HVAC control.
-
MNB-V2-2 Schneider MN VAV BACnet Controller Building Automation New
MNB-V2-2 Schneider MN VAV BACnet Controller Building Automation The Schneider Electric MN VAV BACnet Controller MNB-V2-2 is a BACnet MS/TP-compliant heating/cooling VAV terminal unit controller, adding reheat or dual-duct control capability to the BACnet-open VAV platform for perimeter zones ... -
SXWASPXXX10001 Schneider SmartX Controller AS-P Building Automation New
SXWASPXXX10001 Schneider SmartX Controller AS-P Building Automation The Schneider Electric SmartX Controller AS-P (Part No. SXWASPXXX10001) is the advanced application controller within the EcoStruxure Building Operation (EBO) platform, combining powerful BACnet/IP and MS/TP communication with a ... -
SXWASB36X10001 Schneider SmartX AS-B-36 Building Controller No Display New
SXWASB36X10001 Schneider SmartX AS-B-36 Building Controller No Display New The Schneider Electric SmartX AS-B-36 Building Controller (Part No. SXWASB36X10001) is a 36-point BACnet programmable field controller, offering 50% more I/O than the AS-B-24 for larger AHUs, multi-zone FCU supervision, and ...