SE8350U5B11H Schneider SE8000 Hotel Fan Coil Controller PIR BACnet White

Product Summary
SE8350U5B11H Schneider SE8000 Hotel Fan Coil Controller PIR BACnet White The Schneider Electric SE8350U5B11H is the hotel-specific SE8000 Low-Voltage Fan Coil Room Controller with integrated PIR motion sensor and white fascia. Building upon the SE8350U0B11H, it adds an onboard passive infrared (PIR) ...
Basic Properties
Place of Origin: EU
Brand Name: Schneider
Certification: CE RoHS
Model Number: SE8350U5B11H
Trading Properties
Minimum Order Quantity: 5
Payment Terms: T/T,Western Union
Product Description
SE8350U5B11H Schneider SE8000 Hotel Fan Coil Controller PIR BACnet White
The Schneider Electric SE8350U5B11H is the hotel-specific SE8000 Low-Voltage Fan Coil Room Controller with integrated PIR motion sensor and white fascia. Building upon the SE8350U0B11H, it adds an onboard passive infrared (PIR) occupancy sensor that automatically detects guest presence and adjusts HVAC setpoints — switching from energy-saving unoccupied mode to occupied comfort mode without guest interaction, and returning to setback mode shortly after the room is vacated.
This PIR-driven occupancy response is a key energy management strategy for hotel operators targeting Green Key, ISO 50001, and LEED Building Operations certification. The hotel firmware provides full PMS integration, HRC pairing for lighting and curtain coordination, and BACnet MS/TP / Modbus RTU connectivity.
Technical Specifications
Part Number SE8350U5B11H
Series SpaceLogic SE8000 Hotel Room Controller
Firmware Hotel-specific (H suffix) — PMS/HRC/door lock/PIR integration
Communication Protocols BACnet MS/TP, Modbus RTU
Display Colored capacitive touchscreen, multi-language support
Fascia Color White
PIR Motion Sensor Yes — integrated occupancy detection
Digital Inputs (DI) 2
Analog Inputs (AI) 5 (5–10 V DC)
Analog Outputs (AO) 4 (0–10 V DC)
Digital Outputs (DO) 5
Total I/O Points 16
Integrated RH Sensor Yes — with dehumidification control
Supply Voltage 24 V AC
Relay Output 24 V AC
Setpoint Range 12–37.5°C cooling / 4.5–32°C heating
PIR Occupancy Logic Auto setback when unoccupied, auto comfort restore on detection
Hotel Features Check-in/out setback, PMS, HRC pairing, DND/MUR, PIR occupancy
Certifications BACnet BTL Listed, CE, UL
Stock Status Normally stocked (Thailand, Vietnam and other SE Asia markets)
Key Features
  • Integrated PIR occupancy sensor for automatic HVAC control
  • Hotel-specific firmware with PMS integration
  • HRC pairing for lighting and curtain coordination
  • BACnet MS/TP and Modbus RTU connectivity
  • Energy-saving occupancy-based setback modes
  • Colored capacitive touchscreen with multi-language support
  • Comprehensive I/O configuration for flexible integration
Applications

The SE8350U5B11H is the highest-demand hotel room controller variant in Southeast Asia, where tropical climates make HVAC energy management the single largest controllable cost in hotel operations. International hotel chains in Thailand, Vietnam, Indonesia, and the Philippines specify the PIR variant as standard because guest behavior (leaving the room without adjusting the thermostat) results in significant energy waste without automatic occupancy-based setback.

The PIR sensor eliminates the need for a separate occupancy sensor wired to the controller, reducing installation hardware cost. Combined with PMS check-out setback, the dual-layer occupancy strategy (PIR + keycard) achieves HVAC energy savings of 20–35% compared to manually controlled room thermostats — a compelling ROI for hotel operators targeting sustainability certification.

Product Details
Installation: Flush-mounted
Load Capacity: Supports Motors Up To 100W
Productname: Fan Coil Controllers
Temperaturesensor: Built-in NTC Sensor
Humidityrange: 0% To 95% Non-condensing
Inputvoltage: 24V AC/DC Or 230V AC

Ms. Nora

Sales Manager

Related Products
Send An Inquiry