HRCPBG28R Schneider Hotel Room Controller 28IO BACnet IP Modbus
| Part Number | HRCPBG28R |
|---|---|
| Product Type | Hotel Room Controller |
| Total I/O Points | 28 |
| Digital Inputs (DI) | 8 |
| Analog Inputs (AI) | 8 (pre-configured as DI; direct input type) |
| Digital Outputs (DO) | 8 total — 7x SPST 250V AC 3A relay + 1x SPDT 250V AC 1A relay |
| Analog Outputs (AO) | 4 x 0–10 V DC (load impedance >700 Ohm) |
| Communication Protocol 1 | BACnet/IP + Modbus TCP (via 1x RJ45 Ethernet port with webserver) |
| Communication Protocol 2 | BACnet MS/TP + Modbus RTU (via 2x RS-485 screw terminal) |
| Additional Ports | 1x USB Type A female, 1x USB Mini-B device port, 1x CAN screw terminal |
| Discrete Input Voltage | 24 V AC/DC |
| Discrete Input Current | 2.5 mA |
| Input Impedance | 20,000 Ohm |
| Sensor Power Supply | 24 V DC at 150 mA / 5 V DC at 50 mA (from HRC cartridge) |
| Supply Voltage | 24 V AC +/-10% / 20–38 V DC (not isolated) |
| Supply Frequency | 50/60 Hz |
| Power Consumption | 35 VA / 15 W at 24 V AC/DC |
| Real-Time Clock | Built-in |
| Local Signalling | 4 programmable LEDs |
| Mounting | DIN rail |
| Dimensions (W x H x D) | 144 x 110 x 60.5 mm (5.6 x 4.3 x 2.4 in.) |
| Weight | 380 g (0.82 lb) |
| IP Rating | IP20 (IEC 60529) |
| Pollution Degree | 2 |
| Operating Temperature | -20 to 60 degC (-4 to 140 degF) per UL 60730-1 |
| Storage Temperature | -30 to 70 degC |
| Relative Humidity | 5–95% RH, non-condensing |
| Certifications | CE, UL 60730-1, UL 60730-2-9, CSA E60730-1, CSA E60730-2-9, RoHS, REACH |
| Standards | EN/IEC 60730 |
| Compatible Software | EcoStruxure Building Operation (EBO) |
- Connects to SE8000 Series Room Controller for HVAC temperature control
- Integrates with Property Management Systems (PMS) via EcoStruxure Building Operation (BACnet/IP)
- Enables real-time room status monitoring and energy management
- Provides proactive maintenance alerting from central hotel operations dashboard
- Configuration via built-in embedded web interface — no specialized programming tools required
The HRCPBG28R is the industry-standard hotel guest room controller for full-service and luxury hotel properties worldwide. In a typical 5-star hotel room deployment, a single HRCPBG28R manages up to 7 independent lighting circuit relay outputs (bedside lamps, bathroom, wardrobe, entrance, balcony, nightlight, ceiling), 4 analog outputs for dimmable lighting or curtain motor speed control, and 8 digital/analog inputs for door sensors, card readers, DND/MUR push buttons, and window contacts.
Integration with the Property Management System (PMS) via EcoStruxure Building Operation enables automatic energy-saving setback when guests check out, real-time room occupancy status for housekeeping, and predictive maintenance alerting. The DIN rail form factor fits standard hotel room distribution boards, and the embedded web configuration interface eliminates the need for specialist HVAC commissioning software — reducing installation cost significantly for hotel operators.
-
5WG1258-2DB12 KNX PIR Presence Detector Brightness Sensor 360
5WG1258-2DB12 KNX PIR Presence Detector Brightness Sensor 360 PRODUCT OVERVIEW The 5WG1258-2DB12 (UP 258D12) is a KNX-bus-powered ceiling-mounted presence and motion detector with integrated brightness sensor, designed for intelligent lighting control, HVAC occupancy management, and building ... -
5WG15341DB61 KNX Switch Actuator N534D61 12Ch 16A 20AX 230V
5WG15341DB61 KNX Switch Actuator N534D61 12Ch 16A 20AX 230V The 5WG1534-1DB61 (N 534D61) is a 12-channel KNX switching actuator rated for AC 230 V circuits at 16 AX / 20 AX (200 µF capacitive / fluorescent lamp load), designed for DIN rail installation in electrical distribution boards. It receives ... -
SE8350U0B00H Schneider SE8000 Hotel Fan Coil Controller BACnet Silver
SE8350U0B00H Schneider SE8000 Hotel Fan Coil Controller BACnet Silver Product Overview The Schneider Electric SE8350U0B00H is the silver-fascia hotel variant of the SE8000 Low-Voltage Fan Coil Room Controller. It features hotel-specific firmware with PMS integration, HRC pairing, check-in/out energy ...