SCD2XP2AVP Schneider SpaceLogic Duct CO2 RH VOC PM Sensor BACnet Modbus
The SpaceLogic SCD2XP2AVP is the ultimate, highly integrated flagship indoor air quality (IAQ) duct sensor within the Schneider Electric environmental lineup. Tailored to meet the demands of the post-pandemic era, this powerhouse sensor expands on the multi-sensor platform by integrating an optical laser-scattering particulate matter (PM2.5/PM10) detection module alongside high-precision CO2, relative humidity, temperature, and VOC sensors.
Designed for high-end commercial complexes, high-tech manufacturing, and state-of-the-art medical environments, the SCD2XP2AVP provides HVAC engineers with a complete atmospheric diagnostic tool to measure particulate levels and optimize multi-stage building air filtration.
| Protocol / Communication | Dual-protocol BACnet MS/TP and Modbus RTU (serial RS-485半双工), field-selectable. Supports baud rates from 9600 to 115200 bps. |
|---|---|
| I/O Points & Signals | Networked digital output. No analog terminal blocks. Transmits multiple registers: CO2 (ppm), relative humidity (% RH), temperature, VOC, PM2.5, PM10, and calculated dew point over a single 2-wire serial connection. |
| Power Supply / Voltage | 24 VAC ±15% (50/60 Hz) or 20 to 30 VDC. Peak current draw reaches 150mA during PM sensor active cycles; requires stable Class 2 power supply. |
| Sensor Parameters & Accuracy |
|
| Regulatory & Certifications | UL 916, CE, RCM, FCC Class B, ICES-003, RoHS, RESET Class B compliant. |
| Enclosure & Material | IP65 duct box (PM inlet fitted with protective fine-mesh particulate screen). Constructed from UV-stabilized, high-durability polymers. |
- HVAC HEPA Filtration Diagnostics: Mounted directly downstream of in-duct HEPA filter banks in hospital surgical suites or semiconductor cleanrooms to continuously monitor PM2.5 concentrations, immediately detecting filter breaches.
- Premium Grade-A Smart Offices: Installed in main return ducts of high-density corporate offices to coordinate air purifiers, electrostatic filters, and fresh-air intake cycles during high ambient PM events.
- Advanced Residential & Hotel Ventilation: Ensures superior indoor air quality in luxury hotels and residential towers, monitoring cooking byproducts, dust, and particulate levels.
Schneider SpaceLogic CO2 sensor BACnet
,duct CO2 sensor with Modbus
,SpaceLogic VOC PM room sensor
-
9141047000 Schneider RM4 Voltage Control Relay 3-Phase Base Professional Industrial HVAC Automation Module
9141047000 Schneider RM4 Voltage Control Relay 3-Phase Base Professional Industrial HVAC Automation Module Product Overview The Schneider Electric 9141047000 is a high-specification RM4 Voltage Control Relay 3-Phase Base from the prestigious Zelio RM4 series, engineered to deliver exceptional ... -
TC907-3A4LXPXAB Schneider Touchscreen Thermostat 4-Pipe Black OEM Configurable Luxury Building Interface
TC907-3A4LXPXAB Schneider Touchscreen Thermostat 4-Pipe Black OEM Configurable Luxury Building Interface Product Overview The Schneider Electric TC907-3A4LXPXAB is a high-specification Touchscreen Thermostat 4-Pipe Black OEM from the prestigious SpaceLogic TC900 series, engineered to deliver ... -
TC903-3A4PDPSA Schneider Fan Coil Thermostat 4-Pipe PIR Sensor Modbus RTU Energy Saving Green Building Unit
TC903-3A4PDPSA Schneider Fan Coil Thermostat 4-Pipe PIR Sensor Modbus RTU Energy Saving Green Building Unit Product Overview The Schneider Electric TC903-3A4PDPSA is a high-specification Fan Coil Thermostat 4-Pipe PIR Modbus from the prestigious SpaceLogic TC900 series. Engineered to deliver ...