SCD2XP2AVP Schneider SpaceLogic Duct CO2 RH VOC PM Sensor BACnet Modbus Product Overview The SpaceLogic SCD2XP2AVP is the ultimate, highly integrated flagship indoor air quality (IAQ) duct sensor within the Schneider Electric environmental lineup. Tailored to meet the demands of the post-pandemic ...
Basic Properties
Place of Origin: EU
Brand Name: Schneider
Certification: CE RoHS
Model Number: SCD2XP2AVP
Trading Properties
Minimum Order Quantity: 5
Payment Terms: T/T,Western Union
Product Description
SCD2XP2AVP Schneider SpaceLogic Duct CO2 RH VOC PM Sensor BACnet Modbus
Product Overview

The SpaceLogic SCD2XP2AVP is the ultimate, highly integrated flagship indoor air quality (IAQ) duct sensor within the Schneider Electric environmental lineup. Tailored to meet the demands of the post-pandemic era, this powerhouse sensor expands on the multi-sensor platform by integrating an optical laser-scattering particulate matter (PM2.5/PM10) detection module alongside high-precision CO2, relative humidity, temperature, and VOC sensors.

Designed for high-end commercial complexes, high-tech manufacturing, and state-of-the-art medical environments, the SCD2XP2AVP provides HVAC engineers with a complete atmospheric diagnostic tool to measure particulate levels and optimize multi-stage building air filtration.

Technical Specifications
Protocol / Communication Dual-protocol BACnet MS/TP and Modbus RTU (serial RS-485半双工), field-selectable. Supports baud rates from 9600 to 115200 bps.
I/O Points & Signals Networked digital output. No analog terminal blocks. Transmits multiple registers: CO2 (ppm), relative humidity (% RH), temperature, VOC, PM2.5, PM10, and calculated dew point over a single 2-wire serial connection.
Power Supply / Voltage 24 VAC ±15% (50/60 Hz) or 20 to 30 VDC. Peak current draw reaches 150mA during PM sensor active cycles; requires stable Class 2 power supply.
Sensor Parameters & Accuracy
  • Particulate Matter (PM): Laser-scattering optical particle counter. Range: 0 to 1000 μg/m³. Accuracy: ±10 μg/m³ (0 to 100 μg/m³ range) or ±10% of reading (above 100 μg/m³). Tracks PM1.0, PM2.5, PM4.0, and PM10.
  • CO2 Sensing: Dual-wavelength NDIR. Range: 0 to 2000 ppm. Accuracy: ±30 ppm ±3% of reading.
  • Humidity & Temperature: ±2% RH humidity accuracy; ±0.2°C temperature accuracy.
  • VOC Sensing: Gas-sensitive MOS sensor, auto-calibrating.
Regulatory & Certifications UL 916, CE, RCM, FCC Class B, ICES-003, RoHS, RESET Class B compliant.
Enclosure & Material IP65 duct box (PM inlet fitted with protective fine-mesh particulate screen). Constructed from UV-stabilized, high-durability polymers.
Typical Applications
  • HVAC HEPA Filtration Diagnostics: Mounted directly downstream of in-duct HEPA filter banks in hospital surgical suites or semiconductor cleanrooms to continuously monitor PM2.5 concentrations, immediately detecting filter breaches.
  • Premium Grade-A Smart Offices: Installed in main return ducts of high-density corporate offices to coordinate air purifiers, electrostatic filters, and fresh-air intake cycles during high ambient PM events.
  • Advanced Residential & Hotel Ventilation: Ensures superior indoor air quality in luxury hotels and residential towers, monitoring cooking byproducts, dust, and particulate levels.
• Complete multi-parameter indoor air quality monitoring
• Dual-protocol BACnet MS/TP and Modbus RTU compatibility
• High-precision particulate matter detection
• IP65 rated enclosure for demanding environments
Product Details
Indicator Function: Power, Signal Transmission
Installationmethod: Wall-mounted / Tabletop
Weight: 150 Grams
Sensortype: Multi-functional
Mounting: DIN-rail Mounting
Mountingtype: DIN Rail
Dimensions: 100mm X 60mm X 30mm