Product Summary
Schneider 5123004010 STD100-100 Duct Temp Sensor NTC 1.8K 100mm Product Overview The Schneider Electric 5123004010 (Model: STD100-100) is a highly reliable, passive duct temperature sensor featuring a 100mm (3.94 in.) immersion probe. This precision instrument utilizes a 1.8KΩ (at 25°C) Negative ...
Basic Properties
Place of Origin: EU
Brand Name: Schneider
Certification: CE RoHS
Model Number: 5123004010
Trading Properties
Minimum Order Quantity: 5
Payment Terms: T/T,Western Union
Product Description
Schneider 5123004010 STD100-100 Duct Temp Sensor NTC 1.8K 100mm
Product Overview

The Schneider Electric 5123004010 (Model: STD100-100) is a highly reliable, passive duct temperature sensor featuring a 100mm (3.94 in.) immersion probe. This precision instrument utilizes a 1.8KΩ (at 25°C) Negative Temperature Coefficient (NTC) thermistor specifically designed to match TAC Vista, TAC Xenta, and Continuum controller standards.

As a passive sensor with no complex active electronics, it delivers accurate, drift-free air temperature measurements while providing exceptional long-term field reliability. Ideal for air temperature monitoring inside small-to-medium-sized HVAC ducts.

Technical Specifications
Protocol / Communication None. Passive resistive output.
I/O Points & Signals 1 passive resistive output channel. 2-wire non-polarized terminal block connection.
Power Supply / Voltage Passive (no external power required); drawing excitation voltage from the BAS universal input.
Sensor Parameters
  • Sensor Element: NTC 1.8 kΩ @ 25 °C (77 °F)
  • Measuring Range: -40 to 120°C (-40 to 248°F)
  • Probe Physical Specs: 100 mm (3.94 in.) insertion length, 6 mm diameter brass/stainless-steel probe
  • Measurement Accuracy: ±0.2°C (±0.36°F) at typical room temperatures (0 to 70°C core zone)
Regulatory & Certifications RoHS Compliant, REACH, CE-compliant, WEEE
Enclosure & Material IP65-rated polymer junction box. Weatherproof design to prevent condensation or water vapor ingress.
Typical Applications
  • VAV Box Discharge Air Temperature: Mounted in downstream supply air ducts of VAV terminals to monitor supply temperatures and prevent occupant thermal shock.
  • Small AHU Return Air Sensation: Installed in standard return air paths to measure zone temperature, hardwiring straight to DDC passive inputs.
  • Energy Recovery Ventilation (ERV) Exhaust Monitoring: Measures exhaust air temperatures to analyze real-time ERV heat-exchanger efficiency.
Product Details
Power Consumption: Approximately 10mA
Mountingtype: DIN Rail
System Compatibility: KNX TP1 Standard Protocol Compatible
Controlmethod: Electrical And Manual Override
Motors: 1500 VA, Cosφ ≥ 0.6
Special Feature: Manual Override / Local Operation

Ms. Nora

Sales Manager

Related Products
  • UP 201/12 Touch Sensor Single Without Status LED GAMMA Arina White 5WG1201-2DB12

    UP 201/12 Touch Sensor Single Without Status LED GAMMA Arina White 5WG1201-2DB12 Product Overview The 5WG1201-2DB12 (UP 201/12) is a KNX single touch sensor from the GAMMA arina series, in white, without status LED. One touch zone (2 touch surfaces) controls one independent KNX channel. The flush ...
  • UP 203/13 Touch Sensor Quadruple With Status LED GAMMA Arina White 5WG1203-2DB13

    UP 203/13 Touch Sensor Quadruple With Status LED GAMMA Arina White 5WG1203-2DB13 Product Overview The 5WG1203-2DB13 (UP 203/13) is a KNX quadruple touch sensor from the GAMMA arina series, finished in white with integrated status LEDs. This sophisticated control panel features four touch zones ...
  • 5WG12604AB23 RL260 23 KNX 4 Ch Binary Input AC DC 12 230V

    5WG12604AB23 RL260 23 KNX 4 Ch Binary Input AC DC 12 230V Product Overview The 5WG12604AB23 (RL 260/23) is a KNX binary input module with four independent voltage-sensing channels, each accepting AC or DC signals from 12 V to 230 V. It converts external voltage-based switch signals from conventional ...
Send An Inquiry