UP 588/23 KNX Touch Panel AC/DC 24 V Smart Room Controller 5WG1588-2AB23
The UP 588/23 is a flush-mount KNX touch panel operating at AC/DC 24 V SELV, delivering the same advanced room control capabilities as the AC 230 V UP 588/13 while targeting low-voltage installation environments where SELV power is preferred for safety or regulatory reasons.
Suitable for healthcare facilities, educational institutions, humid environments and international projects following SELV wiring conventions.
The capacitive touchscreen enables intuitive control of KNX-connected systems including:
- Lighting (on/off, dimming)
- Blind management
- HVAC setpoints and mode selection
- Scene activation
- Energy monitoring
KNX S-Mode integration ensures full ecosystem interoperability with ETS commissioning and group/individual addressing support.
The AC/DC 24 V input accepts both AC and DC sources, providing flexibility when connecting to existing 24 V infrastructure, centralized SELV panels or UPS-backed power systems. The device flush-mounts into UP 588E01 enclosure and accepts all S 588/..3 design frame variants.
| Feature | Value |
|---|---|
| Operating voltage | AC/DC 24 V |
| Dimensions (W × H × D) | 161.5 × 135 × 64 mm |
| Communication | KNX S-Mode, 2-wire bus |
| Installation | flush-mount recessed into UP 588E01 |
| Compatible design frames | S 588/12, S 588/13, S 588/14, S 588/15 |
| Data sheet | A6V11637841 |
| Warranty | 24 months |
-
N 526E02 KNX Switch Dim Actuator 8x AC 230V 16A 1-10V DIN Rail Relay UL Standard 5WG1526-1EB02
N 526E02 KNX Switch Dim Actuator 8x AC 230V 16A 1-10V DIN Rail Relay UL Standard 5WG1526-1EB02 This KNX switch/dimming actuator controls eight independent lighting channels for AC 230 V, 50/60 Hz applications and is UL standard certified. Each channel provides a 16 A relay switching output at power ... -
N 264E11 KNX Binary Input Device 8xAC/DC 12-230V 8xPotential-Free DIN Rail 5WG1264-1EB11
N 264E11 KNX Binary Input Device 8xAC/DC 12-230V 8xPotential-Free DIN Rail 5WG1264-1EB11 The KNX binary input device combines eight voltage inputs and eight potential-free contacts in a single compact module, offering flexibility for mixed-signal integration. Voltage inputs cover AC/DC 12 to 230 V, ... -
UP 510/13 KNX Binary Output 2 x AC 230 V 10 A Flush Mount Switch Box Built-in Relay 5WG1510-2AB13
UP 510/13 KNX Binary Output 2 x AC 230 V 10 A Flush Mount Switch Box Built-in Relay 5WG1510-2AB13 This built-in KNX binary output offers two floating relay contacts at AC 230 V / 10 A in an ultra-compact form factor for flush-mount installation. Designed for 60 mm diameter and 60 mm deep switch or ...