N 141/31 KNX/DALI Gateway Twin 2 Channel Broadcast Control for 128 Devices 5WG1141-1AB31
Product Summary
N 141/31 KNX/DALI Gateway Twin 2 Channel Broadcast Control for 128 Devices 5WG1141-1AB31 This twin-channel gateway connects KNX EIB with two independent DALI lines, each accommodating up to 64 DALI-2 ballasts (128 total). It provides broadcast-mode control across both channels: switching, dimming, ...
Basic Properties
Place of Origin:
EU
Certification:
CE RoHS
Model Number:
5WG1141-1AB31
Trading Properties
Minimum Order Quantity:
5
Payment Terms:
T/T,Western Union
Product Description
N 141/31 KNX/DALI Gateway Twin 2 Channel Broadcast Control for 128 Devices 5WG1141-1AB31
This twin-channel gateway connects KNX EIB with two independent DALI lines, each accommodating up to 64 DALI-2 ballasts (128 total). It provides broadcast-mode control across both channels: switching, dimming, scenes (up to 32), color temperature, and RGBW effects for all luminaries together. Status signals report lamp and ballast failures per group and per address for precise fault localization. Universal integrated power supply and half-load bus connection simplify deployment.
Technical Specifications
| Channels | 2 DALI outputs; 64 devices per channel (128 total) |
| Compliance | DALI-2 certified (IEC 62386-101/103); ECG types 0-8 supported |
| Control Mode | Broadcast switching/dimming/scenes/color per channel (group-level) |
| Functions | Configurable stand-alone on bus failure; lamp signal direct mode per DALI device |
| Scenes | One/two-level timer; 32 scenes/channel; ETS ECG-to-group assignment |
| Status | Lamp/ECG failure per group and per device; LED operation/error indication |
| Testing | Start/stop each inverter; save results for duration and long-duration tests |
| Emergency | Self-contained dimming; preset value selection; configuration lockout option |
| Power | AC 110-240 V / DC 120-240 V, 50/60 Hz; 19 V max output; short-circuit resistant; integrated |
| Bus | Half standard load; integrated coupling unit; DIN EN 60715-TH35-7.5 |
| Physical | 72x90x60 mm; 4 MW; IP20; Data sheet AGV10466084; Warranty 24 Months |
Key Features
- Broadcast control for group-level lighting management
- Comprehensive status monitoring and fault localization
- Universal power supply for global deployment
- Integrated coupling unit with half standard bus load
- Emergency lighting functionality with self-contained dimming
Applications
Dual-line DALI installations for cost-effective broadcast KNX control: parking garages, stairwells, back-of-house areas, corridors where group-level switching/dimming/scenes suffice without per-device addressing complexity.
Product Details
Mounting Support:
DIN Rail
Responsetime:
Less Than 100ms
Inputvoltage:
100-240V AC
Installation:
DIN 35mm Standard Rail Mounting
Communication Interface:
DALI
Interfaces:
KNX TP Bus Interface
Configurationsoftware:
Supports PC-based Configuration Tools
Supply Voltage:
24 V DC
Function:
Interface Between DALI Lighting Systems And Other Control Systems
Related Products
-
N 554D31 KNX Universal Dimmer 4x300VA 1x1000VA AC 230V Bus Powered 4 Channel DIN Rail 5WG1554-1DB31
N 554D31 KNX Universal Dimmer 4x300VA 1x1000VA AC 230V Bus Powered 4 Channel DIN Rail 5WG1554-1DB31 The KNX universal dimmer is a four-channel DIN rail device for switching and dimming resistive, inductive, and capacitive loads. Each output is rated up to 300 VA at AC 230 V, and adjacent outputs can ... -
JB 260C23 KNX Built-In Binary Input 4xAC/DC 12-230V UL/NEMA Junction Box Mount 5WG1260-4CB23
JB 260C23 KNX Built-In Binary Input 4xAC/DC 12-230V UL/NEMA Junction Box Mount 5WG1260-4CB23 The KNX binary input device is a built-in module designed for installation in or on UL/NEMA junction boxes using a 1/2 inch threaded connection. It provides four AC/DC 12 to 230 V inputs for connecting ... -
N 263D31 KNX Binary Input Module 4xAC/DC 10-230V DIN Rail LED Status Display 5WG1263-1DB31
N 263D31 KNX Binary Input Module 4xAC/DC 10-230V DIN Rail LED Status Display 5WG1263-1DB31 Product Overview The KNX binary input module accepts four voltage inputs covering AC/DC 10 to 230 V, making it suitable for connecting active sensors, relay contacts, and voltage signals directly. Each input ...