N 141/32 KNX DALI Gateway Twin 2 Lines Multi Master Controller 128 Devices DIN Rail 5WG1141-1AB32
This twin-channel Multi-Master Gateway doubles across two independent DALI lines, each a full DALI-2 certified master with up to 64 ECGs, 8 presence sensors, and 8 brightness sensors — 128 devices total. Every channel delivers independent switching, dimming, Tunable White, RGB(W), logic functions, overrides, and per-address monitoring. Supports HCL schedules, DCA sensor assignment, and comprehensive detection.
| Specification | Details |
|---|---|
| Channels | 2 lines; 64 ECGs/line (128 total); 8 presence + 8 brightness sensors/line |
| Protocol | DALI Multi-Master; DALI-2 (IEC 62386-101/-103); ECG types 0–8 (Ed.1 & 2) |
| Color Control | D/T8 Tunable White Tc; RGB/RGB(W); HCL schedule support (part 209) |
| Per-Channel Control | Independent switch/dim/value/color temp; 2 logic functions; overrides/channel |
| Monitoring | Lamp/ECG failure per group/device; LED status/output |
| Scenes & Timing | Up to 16 scenes/output; 1 or 2-level timer; cycle counter with threshold |
| Energy Management | Stand-by-area analysis (16 channels/output); occupancy-based actuator activation |
| Brightness Control | 16 two-level + 16 constant light controllers/main group |
| Calculators | 16 brightness calculators per output; DCA via ETS |
| Power Supply | Integrated AC/DC 220–240 V; max 19 V short-circuit resistant; half bus load each |
| Wiring | Maintenance-free push-in terminals; 0.5–2.5 mm² stranded/multi-core |
| Mounting & Dimensions | DIN EN 60715-TH35-7.5; 72x55x90 mm; 4 MW; Data sheet AGV10466084; Warranty 24 Months |
-
N 263D51 KNX Binary Input Module 8xAC/DC 10-230V, DIN Rail LED Status Display 5WG1263-1DB51
N 263D51 KNX Binary Input Module 8xAC/DC 10-230V, DIN Rail LED Status Display 5WG1263-1DB51 The KNX binary input module delivers eight voltage inputs across AC/DC 10 to 230 V, allowing direct connection of active sensors, relay contacts, and signal sources. Each input is equipped with a direct ... -
UP 510/13 KNX Binary Output 2 x AC 230 V 10 A Flush Mount Switch Box Built-in Relay 5WG1510-2AB13
UP 510/13 KNX Binary Output 2 x AC 230 V 10 A Flush Mount Switch Box Built-in Relay 5WG1510-2AB13 This built-in KNX binary output offers two floating relay contacts at AC 230 V / 10 A in an ultra-compact form factor for flush-mount installation. Designed for 60 mm diameter and 60 mm deep switch or ... -
UP 510/03 KNX Binary Output 2 x AC 230 V 10 A with Mounting Frame and BTI Interface Flush Box 5WG1510-2AB03
UP 510/03 KNX Binary Output 2 x AC 230 V 10 A with Mounting Frame and BTI Interface Flush Box 5WG1510-2AB03 This KNX binary output provides two floating relay contacts at AC 230 V / 10 A in a compact built-in design for flush-mount switch or socket boxes. Supplied with a mounting frame and BTI ...