N 502/02 KNX Combi Switching Actuator 8xAC 230V 16A 8 Binary Inputs DIN Rail 5WG1502-1AB02
The KNX combi switching actuator integrates eight relay outputs and eight potential-free binary inputs in a single modular DIN rail device. Each output is rated for AC 230 V at 16 A, making it ideal for demanding load switching applications including lighting, shutters, and heating circuits.
The unit features an integrated power supply and bus coupling unit, maintaining functionality even without bus power or during communication interruptions. Front-mounted buttons enable toggling between bus and direct modes, with each output capable of local switching via short button presses or configurable time switch relay behavior.
- Switching status transmission
- Single-button and two-button dimming control
- Shutter and blind control functionality
- 1-bit and 8-bit scene control
- 16-bit floating point value transmission
- Group control capabilities
- Selectable blocking/releasing logic
- AND/OR logic operations
- Configurable switching states on mains/bus failure and recovery
- Variable output delay times
- Integrated 8-bit scene linking
| Communication Protocol | KNX |
| Relay Outputs | 8x AC 230 V |
| Binary Inputs | 8 potential-free |
| Rated Contact Current | 16 A per output |
| Power Supply | Integrated 230 V |
| Device Width | 8 MW (144 mm) |
| Mounting | DIN rail per TH35 EN 60715 |
| Protection Class | IP 20 |
| Dimensions (W x H x D) | 144 x 90 x 60 mm |
| Warranty | 24 months |
- Commercial building automation systems
- Office lighting and shading control
- Hotel guest room management
- Multi-zone HVAC actuation
- Medium-scale residential KNX installations
-
N 141/32 KNX DALI-2 Gateway Twin 2 Lines IP Interface 128 ECG RGBW Tunable White 5WG1141-1AB32
N 141/32 KNX DALI-2 Gateway Twin 2 Lines IP Interface 128 ECG RGBW Tunable White 5WG1141-1AB32 This advanced KNX/DALI-2 gateway twin manages two independent DALI lines as a multi-master controller and incorporates an IP interface with Ethernet connection via RJ45 for remote commissioning, diagnostic... -
UP 141/71 DALI-2 Push Button Interface 4-Fold Flush Mount Wall Switch ECG Control 5WG1141-2AB71
UP 141/71 DALI-2 Push Button Interface 4-Fold Flush Mount Wall Switch ECG Control 5WG1141-2AB71 Product Overview This four-fold DALI-2 push-button interface is designed for flush mounting behind conventional wall switches, enabling up to four switch inputs to control DALI electronic control gears ... -
N 502/02 KNX Combi Switching Actuator 8xAC 230V 16A + 8 Binary Inputs DIN Rail 5WG1502-1AB02
N 502/02 KNX Combi Switching Actuator 8xAC 230V 16A + 8 Binary Inputs DIN Rail 5WG1502-1AB02 The KNX combi switching actuator combines eight relay outputs and eight potential-free binary inputs in a single modular device. Each output is rated for AC 230 V at 16 A, making it suitable for demanding ...