S 193/01 KNX TP Bus Terminal 2-Pole 4 Plug-in Connectors Red Dark Gray Polarity 5WG1193-8AB01
The S 193/01 KNX bus terminal is a compact 2-pole connection block designed for joining KNX bus devices to the bus cable. It supports connection of up to four bus cables, making it ideal for distributing bus lines inside devices or small enclosures.
The terminal comprises two interlocked clamp parts in red and dark gray, each equipped with four screwless plug-in terminals for solid conductors with diameters from 0.6 to 0.8 mm. Its compact dimensions allow installation in tight spaces within KNX devices, wall boxes, and control panels.
The terminal provides reliable, color-coded polarity connection and simplifies maintenance by allowing plug-in termination without screwdrivers. The color-coded red and dark gray clamp parts ensure correct KNX bus polarity alignment and reduce installation errors in dense wiring environments.
| Type | 2-pole bus terminal |
| Bus Cables | Up to 4 |
| Clamp Parts | Red and dark gray |
| Terminals | 4 screwless plug-in terminals per clamp part |
| Conductor Diameter | Solid conductors 0.6 to 0.8 mm |
| Rated For | Standard KNX bus voltage and current |
| Dimensions (W x H x D) | 10 x 12.4 x 10 mm |
| Warranty | 24 months |
- KNX device internal wiring
- Bus cable distribution in wall boxes
- Connection of KNX sensors and actuators
- Small panel terminations
- Retrofit installations
- Thermostat and pushbutton connections
- Actuator branch wiring
- Any location requiring compact, polarity-secure bus connections
-
N 140/13 KNX Line Backbone Coupler 64 Byte Telegrams Repeater DIN Rail 2MW 5WG1140-1AB13
N 140/13 KNX Line Backbone Coupler 64 Byte Telegrams Repeater DIN Rail 2MW 5WG1140-1AB13 The N 140/13 KNX line and backbone coupler enables data exchange between two KNX bus lines with telegrams of up to 64 bytes. It can serve as a line coupler, backbone coupler, or repeater, including electrical ... -
N 120/02 KNX External Bus Choke 640mA for Power Supply Unchoked Output DIN 5WG1120-1AB02
N 120/02 KNX External Bus Choke 640mA for Power Supply Unchoked Output DIN 5WG1120-1AB02 Product Overview The N 120/02 KNX choke is a 640 mA external inductive filter designed for use with KNX power supplies that do not have an integrated choke, or for connection to the unchoked output of N 125/x2 ... -
N 141/14 KNX DALI-2 Gateway 1 Output 64 ECG IP Interface DT8 Tunable White RGBW 5WG1141-1AB14
N 141/14 KNX DALI-2 Gateway 1 Output 64 ECG IP Interface DT8 Tunable White RGBW 5WG1141-1AB14 This KNX/DALI gateway provides a single DALI output for communication with up to 64 electronic control gears via 64 intelligent channels and is DALI-2 certified as a multi-master controller per IEC 62386...