CAR/U 4.2.1.1-84 ABB SpaceLogic Multi-Sensor CO2 Humidity Temp Pressure Plus Version White
The ABB CAR/U4.2.1.1-84 is a high-precision multi-functional room air quality sensor from the SpaceLogic range, purpose-built for integration into professional KNX building automation systems. Housed in an elegant Studio White finish, this Plus Version Multi-sensor is the ultimate tool for monitoring and maintaining a healthy and comfortable indoor environment in modern commercial and high-end residential buildings.
By consolidating multiple environmental parameters into a single, compact wall-mounted unit, the CAR/U4.2.1.1-84 reduces wall clutter while providing the granular data required by advanced Building Management Systems (BMS) to execute energy-efficient ventilation and climate control strategies. Engineered for longevity and reliability, it utilizes state-of-the-art sensing elements that are factory-calibrated for long-term stability.
| Product Model | CAR/U4.2.1.1-84 |
|---|---|
| Color Finish | Studio White |
| Communication Protocol | KNX TP1 (S-Mode / PL-Link) |
| Measured Parameters | Carbon Dioxide (CO2), Relative Humidity (RH), Temperature, Atmospheric Pressure |
| CO2 Sensor Technology | Non-dispersive Infrared (NDIR) with dual-beam technology for drift compensation |
| CO2 Measurement Range | 0 to 5,000 ppm |
| Humidity Sensor Type | Thin-film capacitive with +/- 2% RH accuracy |
| Temperature Accuracy | +/- 0.2 degC typical at 25 degC |
| Atmospheric Pressure Range | 300 to 1,100 hPa |
| Operating Voltage | Bus-powered via KNX line (DC 24-30 V SELV) |
| Bus Load | approx. 10 mA |
| External Inputs | 5 binary inputs for connecting conventional floating contacts (switches/window contacts) |
| Operating Temperature | -5 degC to +45 degC (standard indoor operational range) |
| IP Rating | IP20 (Indoor mounting) |
| Flame Retardance | UL 94 V-0 compliant halogen-free housing |
| Certifications | CE Marked, RoHS, REACH, KNX Certified, Green Premium Environmental Data |
The CAR/U4.2.1.1-84 is specifically deployed in environments where indoor air quality (IAQ) is operationally critical. In large open-plan office spaces and executive boardrooms, the integrated CO2 and humidity sensing enables demand-controlled ventilation (DCV).
- As occupancy increases and CO2 levels rise, the sensor triggers the BMS to increase fresh air intake, ensuring cognitive performance and health while avoiding the energy waste of over-ventilating unoccupied zones
- In laboratory and healthcare environments, the atmospheric pressure monitoring is used to maintain the required pressure differentials between rooms, preventing cross-contamination
- The integrated binary inputs allow for the direct connection of window contacts, automatically setting back the HVAC system to energy-saving mode when a window is opened — a mandatory strategy for energy code compliance
Its sophisticated Studio White finish ensures that technical performance is matched by aesthetic excellence in modern architectural designs.
-
LSS100300 Schneide SpaceLogic KNX BMS Industrial Grade IP Gateway BMS System
Schneider LSS100300 KNX-BMS IP Gateway: BTL-certified 3-in-1 device integrating router, interface & power supply. Enables seamless BACnet/KNX protocol conversion with 100% compatibility. Reduces installation costs by 75% with ultra-low 2W power consumption for commercial building automation. -
MTN676090 Schneider SpaceLogic KNX Basic Logic Module REG-K DIN Rail Installation