LSS100300 Schneider SpaceLogic KNX BMS IP BACnet/IP Gateway Supplier

Product Summary
Schneider LSS100300 KNX-BMS IP Gateway: BTL-certified 3-in-1 device integrating router, interface & power supply. Enables seamless BACnet/KNX protocol conversion with 100% compatibility. Reduces installation costs by 75% with ultra-low 2W power consumption for commercial building automation.
Basic Properties
Place of Origin: EU
Brand Name: Schneider
Certification: CE RoHS
Model Number: LSS100300
Trading Properties
Minimum Order Quantity: 5
Payment Terms: T/T,Western Union
Product Description
LSS100300 Schneider SpaceLogic KNX BMS IP BACnet/IP Gateway Supplier

LSS100300 is a Schneider SpaceLogic KNX BMS IP / BACnet/IP gateway designed for integrating KNX installations with building management systems. It helps connect KNX building automation devices with EcoStruxure Building Operation and BMS-level control platforms, making it suitable for hotels, offices, commercial buildings and large facility projects.

We supply Schneider KNX and BAS components for project purchasing, replacement, and BOQ quotation. Send us your model list, system requirement or project BOQ to confirm price, stock and lead time for LSS100300 and related SpaceLogic KNX products.

Quick Purchase Information
Item Details
BrandSchneider Electric
Product RangeSpaceLogic KNX
ModelLSS100300
Product TypeKNX BMS IP / BACnet/IP gateway
Product NameBACnet/IP gateway, SpaceLogic KNX, BMS
Main ApplicationKNX integration with BMS / EcoStruxure Building Operation
Common ProjectsHotel, office building, commercial building, public building, smart building
Buyer TypeKNX integrator, BMS/BAS contractor, MEP/ELV contractor, building automation supplier
DocumentsProduct datasheet, user guide and installation document available on request
Quote SupportSend BOQ, model list, system diagram, required quantity and destination country
Product Description

Schneider LSS100300 is a SpaceLogic KNX BMS IP gateway for projects where KNX installations need to be integrated into a building management system. It is designed for building automation applications that require communication between KNX field-level devices and BMS-level monitoring or control.

In hotel, office and commercial building projects, KNX is often used for lighting control, room control, push buttons, sensors and automation functions. A BMS platform may then need to monitor or control selected KNX data points at the building level. LSS100300 is positioned for this type of KNX-to-BMS integration requirement.

Typical KNX devices connected in the project may include switch actuators, DALI gateways, presence detectors, push buttons, room controllers, power supplies and other SpaceLogic KNX components. For project purchasing, buyers can send the complete BOQ so related Schneider KNX and BAS products can be quoted together.

Application Scenarios
Scenario How LSS100300 Is Used
Hotel BMS integrationConnects KNX room or lighting automation data to the building management system
Office building automationHelps BMS monitor and manage selected KNX lighting or room-control data points
Commercial building projectsSupports KNX integration in shopping malls, mixed-use buildings and facility projects
Public building automationSuitable for projects where KNX systems need BMS-level visibility and control
KNX project upgradeUsed when an existing KNX installation needs to be connected to a BMS platform
Schneider EcoStruxure projectRelevant when KNX installations need integration with EcoStruxure Building Operation
When to Choose LSS100300

Choose LSS100300 when the project requirement includes:

  • Schneider SpaceLogic KNX system integration
  • KNX installation connection to BMS
  • BACnet/IP gateway requirement for KNX/BMS architecture
  • EcoStruxure Building Operation integration
  • Hotel, office or commercial building automation
  • Centralized monitoring or management of KNX data points
  • Schneider KNX project BOQ purchasing

Before ordering, please confirm:

  • Project BMS platform
  • Required data points
  • KNX topology
  • Whether EcoStruxure Building Operation is involved
  • Required gateway function
  • Quantity and delivery schedule
  • Whether other KNX devices are needed together
Important Note for HVAC / VRF Projects

Some customers ask for LSS100300 when they have HVAC, VRF or BMS integration requirements. The correct product depends on the full system architecture.

For VRF or HVAC integration, please provide:

  • VRF / HVAC brand and model
  • Indoor unit quantity
  • Existing interface or gateway model
  • Required protocol: KNX, BACnet/IP, Modbus or BMS connection
  • Required control points: on/off, mode, setpoint, fan speed, temperature, error status
  • Existing KNX system diagram or BMS specification

LSS100300 may be relevant when the project needs KNX to BMS/BACnet/IP integration, but the final solution should be checked according to the VRF interface, protocol and BMS design.

Product FAQ
Q1: What is Schneider LSS100300 used for?

LSS100300 is a Schneider SpaceLogic KNX BMS IP / BACnet/IP gateway used for integrating KNX installations with BMS-level control and monitoring platforms, especially in building automation projects.

Q2: Is LSS100300 the same as LSS100200 spaceLYnk?

No. LSS100300 is positioned as a KNX BMS IP / BACnet/IP gateway, while LSS100200 spaceLYnk is a logic controller and multi-protocol gateway used for KNX, Modbus and BACnet integration. The correct model should be selected according to the project architecture.

Q3: Can LSS100300 be used with EcoStruxure Building Operation?

Schneider Electric describes LSS100300 as a multifunctional device that allows integration of KNX installations within EcoStruxure Building Operation. Please confirm the project requirement and BMS architecture before ordering.

Q4: Can LSS100300 be used for VRF to KNX integration?

It depends on the full system design. LSS100300 may be relevant when KNX data needs to be integrated with a BMS through BACnet/IP, but VRF integration also depends on the VRF brand, interface and protocol. Please send the VRF model, indoor unit quantity and system diagram for checking.

Q5: What information should I send for quotation?

Please send the model number, quantity, destination country, project BOQ, system diagram, required protocol and delivery time. For BMS projects, please also send the required data points and BMS platform information.

Q6: Can you supply LSS100300 with other Schneider KNX products?

Yes. We can quote LSS100300 together with Schneider KNX switch actuators, DALI gateways, presence detectors, push buttons, power supplies, logic modules and other SpaceLogic KNX components.

Q7: Do you ship LSS100300 to the Middle East?

Yes. We can arrange shipping to UAE, Saudi Arabia, Qatar, Kuwait, Oman, Bahrain and other overseas markets. Please send quantity and destination country for freight and lead-time confirmation.

Q8: Can you provide datasheet or installation documents?

Yes. Datasheet, user guide and installation documents can be provided on request. You can also send us the project requirement, and we will help check related documents before quotation.

Product Details
Safetycertifications: CE, RoHS
Controlcompatibility: Compatible With KNX, Modbus, BACnet
Humidity: 10% To 90% Non-condensing
Product Id: LSS100300
Power Supply: KNX Bus-powered (DC 21-30V)
Power Consumption: 5W
Mounting Support: DIN Rail
Supply Voltage: 24 V DC
Controlchannels: Up To 64 DALI Devices
Dimensions: 120mm X 90mm X 60mm
Configurationsoftware: Supports PC-based Configuration Tools
Color: White
Brand: Schneider

Ms. Nora

Sales Manager