006920221 Schneider STP300-100 -50/50 Loop Thermo Transmitter 4-20mA 100mm Stem Two Wire Water Signal

Product Summary
Schneider STP300-100 -50/50 Loop Thermo Transmitter Part Number: 006920221 Product Code: STP300-100 -50/50 4-20mA 100mm Stem Two Wire Water Signal Product Overview Measurement Precision: Every hydronic control loop depends on the accuracy of its sensing probe. The 006920221 is engineered as a ...
Basic Properties
Place of Origin: EU
Brand Name: Schneider
Certification: CE RoHS
Model Number: 006920221
Trading Properties
Minimum Order Quantity: 5
Payment Terms: T/T
Product Description
Schneider STP300-100 -50/50 Loop Thermo Transmitter
Part Number: 006920221
Product Code: STP300-100 -50/50
4-20mA 100mm Stem Two Wire Water Signal
Product Overview
Measurement Precision: Every hydronic control loop depends on the accuracy of its sensing probe. The 006920221 is engineered as a precision measurement instrument, featuring a stainless-steel stem that installs through a separate closed pocket, allowing element replacement without draining the circuit.
Robust Construction: A sealed transition separates wet metal from cable connections, while the factory-fitted gland protects against condensation, dust, and wash-down spray. This passive device requires no firmware updates or battery replacements, drawing minimal current from the controller's measuring circuit.
Bipolar Range Advantage: Specifically designed for circuits that may drop below freezing, the bipolar temperature span prevents signal clipping at low temperatures, ensuring accurate monitoring throughout the entire operational range.
Each unit undergoes traceable temperature reference calibration before packaging, with documentation suitable for commissioning records, handover dossiers, and energy-audit evidence.
Technical Specifications
Part Number 006920221
Product Code STP300-100 -50/50
Product Family STP300 (4-20 mA transmitter)
Sensing Element Electronic temperature transmitter with linearised current output
Signal Path / Wiring Two-wire loop carrying both supply and signal
Supply Voltage 15 to 36 V DC loop supply
Probe Length 100 mm (3.94 in.)
Temperature Range -50 to +50°C (-58 to +122°F)
Accuracy ±0.4% of range
Mounting Immersion through separate closed pocket (pocket ordered separately)
Stem Material Stainless steel, corrosion resistant
Cable 2 m PVC-sheathed flying lead with 20 mm (0.79 in.) fitting and gland
Housing Sealed plant-room construction, IP-rated against condensation
Response Curve matched to host controller input
Approvals CE, RoHS, REACH; Schneider Green Premium documentation
Application Scenarios
This transmitter variant is specifically engineered for demanding environments including:
  • Cold-store pipework and refrigeration systems
  • Ice-water loops and chilled water circuits
  • Outdoor hydronic circuits and exposed piping
  • Chilled accumulators during pull-down phases
The bipolar temperature range ensures measurement remains within the calibrated band during sub-zero conditions, enabling frost-protection systems to operate on accurate data rather than assumptions. The 4-20 mA signal protocol maintains integrity over long cable runs, making it ideal for installations where control panels are located at significant distances from monitored piping.
Product Details
Highlight:

Schneider STP300-100 loop thermo transmitter

,

4-20mA water signal transmitter

,

100mm stem room sensor

Function: Controls Electrical Switches Remotely
Operating Mode: Manual KNX Bus System
Protection Rating: IP20 Protection Level
Material: ABS Plastic Housing With UV Protection
Inputtype: Binary Switch Input
Powersupply: Battery / USB Powered

Ms. Nora

Sales Manager

Related Products
Send An Inquiry