006920301 Schneider STP300-200 0/100 Loop Thermo Transmitter 4-20mA 200mm Stem District Heat Signal

Product Summary
Schneider STP300-200 0/100 Loop Thermo Transmitter Product Overview Why this part exists: Every hydronic control loop inherits the accuracy of the probe that feeds it, which is why the 006920301 is treated as a measurement instrument rather than an accessory. Catalogued by Schneider Electric inside ...
Basic Properties
Place of Origin: EU
Brand Name: Schneider
Certification: CE RoHS
Model Number: 006920301
Trading Properties
Minimum Order Quantity: 5
Payment Terms: T/T
Product Description
Schneider STP300-200 0/100 Loop Thermo Transmitter
Product Overview
Why this part exists:
Every hydronic control loop inherits the accuracy of the probe that feeds it, which is why the 006920301 is treated as a measurement instrument rather than an accessory. Catalogued by Schneider Electric inside the STP300 (4-20 mA transmitter) range, it carries a stainless-steel stem that is lowered into the water stream through a separate closed pocket, so the sensing element can be swapped during a maintenance window without draining the circuit.
How this variant is chosen:
Choose this combination when the pipe is large and insulated but the duty is ordinary heating: a long stem for reach, a standard span for resolution.

Behind the stem a moulded, sealed transition separates wet metal from the cable, and the factory-fitted gland keeps condensation, dust and wash-down spray away from the conductor. Because the device is passive it draws no meaningful current, needs no firmware update and has no battery to schedule for replacement; the controller's own measuring circuit supplies the excitation and reads the returning value. Every unit is checked against a traceable temperature reference before packing, and the paperwork that travels with it suits commissioning records, handover dossiers and energy-audit evidence.

Technical Specifications
Part Number 006920301
Product Code STP300-200 0/100
Product Family STP300 (4-20 mA transmitter)
Sensing Element Electronic temperature transmitter with linearised current output
Signal Path / Wiring Two-wire loop carrying both supply and signal; read across an external load resistor
Supply 15 to 36 V DC loop supply
Probe Length 200 mm (7.87 in.)
Temperature Range 0 to +100°C (32 to +212°F)
Accuracy ±0.4% of range
Mounting Immersion through separate closed pocket (pocket ordered separately)
Stem Material Stainless steel, corrosion resistant
Cable 2 m PVC-sheathed flying lead with 20 mm (0.79 in.) fitting and gland
Housing Sealed plant-room construction, IP-rated against condensation
Response Curve matched to the host controller input
Approvals CE, RoHS, REACH; Schneider Green Premium documentation
Application Scenarios

District-heating interface units and central plant manifolds that feed several building zones are the classic application. Those headers are typically well insulated, so the probe must clear the cladding, yet the temperatures involved sit comfortably inside a conventional heating band where a concentrated span delivers the best usable resolution.

The 200 mm stem also reduces the influence of pipe-wall temperature on the reading, which stabilises supply and return differentials used for pump control and energy allocation. Where a site is billing heat between tenants or reporting consumption for compliance, that stability translates directly into defensible numbers rather than estimates.

Product Details
Highlight:

Schneider STP300-200 loop thermo transmitter

,

4-20mA district heat signal transmitter

,

200mm stem room temperature sensor

Product Series: Schneide SpaceLogic KNX Series
Indicator Function: Power, Signal Transmission
Protection: Electrical Isolation Between Segments
Installation Site: False Ceiling Mounting, Indoor F
Measured Parameters: Temperature, Humidity, CO2, VOC, Light
Function: Controls Electrical Switches Remotely
Communication Protocols: Wi-Fi, Zigbee, Z-Wave, Or RF

Ms. Nora