5123132010 Schneider STP200-100 Hydronic Flow Thermo Element 100mm Rigid Stem 10k Ohm Curve Type 2

Product Summary
5123132010 Schneider STP200-100 Hydronic Flow Thermo Element 100mm Rigid Stem 10k Ohm Curve Type 2 Product Overview Why this part exists Every hydronic control loop inherits the accuracy of the probe that feeds it, which is why the 5123132010 is treated as a measurement instrument rather than an ...
Basic Properties
Place of Origin: EU
Brand Name: Schneider
Certification: CE RoHS
Model Number: 5123132010
Trading Properties
Minimum Order Quantity: 5
Payment Terms: T/T
Product Description
5123132010 Schneider STP200-100 Hydronic Flow Thermo Element 100mm Rigid Stem 10k Ohm Curve Type 2
Product Overview
Why this part exists

Every hydronic control loop inherits the accuracy of the probe that feeds it, which is why the 5123132010 is treated as a measurement instrument rather than an accessory. Catalogued by Schneider Electric inside the STP200 (10 kOhm, curve type 2) range, it carries a stainless-steel stem that is lowered into the water stream through a separate closed pocket, allowing the sensing element to be swapped during maintenance without draining the circuit.

Behind the stem, a moulded, sealed transition separates wet metal from the cable, and the factory-fitted gland protects against condensation, dust, and wash-down spray. As a passive device, it draws no meaningful current, requires no firmware updates, and has no battery replacement schedule—the controller's measuring circuit supplies excitation and reads returning values.

Each unit is checked against a traceable temperature reference before packing, with documentation suitable for commissioning records, handover dossiers, and energy-audit evidence.

How this variant is chosen

The 100 mm stem is the mainstream solution for distribution pipework up to approximately DN80, ensuring the tip reaches the moving core of the flow rather than lingering in the boundary layer along the wall.

Technical Specifications
Part Number 5123132010
Product Code STP200-100
Product Family STP200 (10 kOhm, curve type 2)
Sensing Element Passive 10 kOhm thermistor, curve type 2
Signal Path / Wiring Two/three-wire resistance loop wired to controller analogue input
Supply None required; excited by controller measuring circuit
Probe Length 100 mm (3.94 in.)
Temperature Range Chilled and hot water duty per STP200 curve
Accuracy Matched to standard HVAC control grade for this curve
Mounting Immersion through separate closed pocket (pocket ordered separately)
Stem Material Stainless steel, corrosion resistant
Cable 2 m PVC-sheathed flying lead with 20 mm (0.79 in.) fitting and gland
Housing Sealed plant-room construction, IP-rated against condensation
Response Curve matched to host controller input
Approvals CE, RoHS, REACH; Schneider Green Premium documentation
Application Scenarios

On primary and secondary heating mains, this probe provides the controller with a clean supply and return differential—the raw material for delta-T optimization and pump staging. These two functions represent where most savings in a hydronic system are achieved.

Equally suitable for chilled headers serving air-handling units, it enables stable readings that allow plant sequencing of chillers against genuine demand rather than fixed schedules.

With a stem length optimized for standard pockets yet compact enough for normal plant-room manifolds, this variant is frequently held as a spare on site and replaced most often during routine sensor audits.

Product Details
Highlight:

Schneider STP200-100 hydronic flow thermo element

,

100mm rigid stem room sensor

,

10k ohm curve type 2 thermo element

Operating Humidity: 0% To 95% Non-condensing
Response Time: Less Than 10 Seconds
Indicator Function: Power, Signal Transmission
Data Logging: Supports Local And Cloud Data Storage
Measurement Range: Temperature: -20°C To 50°C, Humidity: 0% To 100%
Accuracy: ±0.5°C For Temperature, ±3% For Humidity