SXWHHREL10001 Schneider SpaceLogic RP 10 Channel Relay Expansion Module 12 Digital Inputs DIN Rail Mount
Product Summary
SXWHHREL10001 Schneider SpaceLogic RP 10 Channel Relay Expansion Module 12 Digital Inputs DIN Rail Mount The SXWHHREL10001, catalogued by Schneider Electric as CRS-HH-REL-10, is a relay expansion module from the SpaceLogic RP accessory family within the EcoStruxure Connected Room Solutions ...
Basic Properties
Place of Origin:
EU
Brand Name:
Schneider
Certification:
CE RoHS
Model Number:
SXWHHREL10001
Trading Properties
Minimum Order Quantity:
5
Payment Terms:
T/T
Product Description
SXWHHREL10001 Schneider SpaceLogic RP 10 Channel Relay Expansion Module 12 Digital Inputs DIN Rail Mount
The SXWHHREL10001, catalogued by Schneider Electric as CRS-HH-REL-10, is a relay expansion module from the SpaceLogic RP accessory family within the EcoStruxure Connected Room Solutions architecture. Its purpose is narrow and useful: it adds switched outputs and volt-free inputs to a room controller that has run out of them.
Product Overview
Ten relay channels provide hard contacts for lighting groups, blind or curtain motors and small fan loads, while twelve digital inputs accept potential-free contacts from window switches, occupancy detectors, card readers or flow switches. The relay outputs are rated for the inrush current that modern LED drivers present, which is where generic relay boards usually disappoint, and the same outputs can drive 120 or 240 V AC blind motors directly without external slave relays. The module mounts on DIN rail and extends the host controller's own addressing scheme, so the engineering tool sees one device with a larger point count rather than two devices to coordinate.
Specification Summary
| Specification | Details |
|---|---|
| Product Type | Controller expansion module, relay and digital input |
| Order Number | SXWHHREL10001 |
| Manufacturer Reference | CRS-HH-REL-10 |
| Product Family | SpaceLogic RP controller expansion modules, EcoStruxure Connected Room Solutions |
| Relay Outputs | 10 channels, 24 V DC relay outputs |
| Digital Inputs | 12 channels for potential-free contacts |
| Load Capability | High inrush current capability, suited to LED lighting loads |
| Blind Control | Direct support for 120 / 240 V AC blind motors |
| Mounting | DIN rail |
| Host Compatibility | SpaceLogic RP room controllers; engineering via EcoStruxure Building Operation |
| Compliance | CE marking; RoHS and REACH declarations held by Schneider Electric |
System Integration Notes
The expansion module is addressed as part of the host controller, so the engineering workflow is to define the room model once and then bind the extra outputs and inputs into it, rather than commissioning a second device with its own network identity.
Relay outputs should be grouped so that a single room or zone shares one channel where possible, which keeps the point count down and simplifies later modification. Digital inputs are typically wired to volt-free contacts only; applying a foreign voltage to an input is the most frequent cause of a dead channel and is easily avoided by checking the field wiring before energising.
Because LED lighting loads vary widely in inrush behaviour, the practical load rating per channel should be confirmed against the actual driver datasheet rather than assumed from the steady-state wattage.
Application Scenarios
- Hotel Guest Rooms: Use the combination of relay outputs and digital inputs to manage lighting scenes, curtain motors and key-card or presence logic from a single room controller.
- Office Projects: Apply the module where a floor plate has more lighting circuits than the controller was originally specified for, avoiding the cost of a second controller.
- Meeting Rooms: With motorised blinds and layered lighting rely on the direct blind-motor capability to remove an external relay panel.
- Educational and Healthcare Buildings: Use the digital inputs for window and door contacts that feed energy and security logic.
- Retrofit Projects: In occupied buildings favour the DIN rail format because the additional I/O can be added inside an existing panel during a planned shutdown.
Product Details
Highlight:
Schneider SpaceLogic RP relay module
,10 channel DIN rail relay
,12 digital input expansion module
Control Modes:
Automatic KNX Sensor Linkage
Protection:
Electrical Isolation Between Segments
Mounting:
DIN-rail Mounting In Electrical Cabinet
Type:
Automation Control System
Load Capacity:
Supports Motors Up To 100W
Related Products
-
L5504AMP Schneider Clipsal C-Bus Dimming Interface 4 Way 0-10V DC Output Module DIN Rail 240V Unit
L5504AMP Schneider Clipsal C-Bus Dimming Interface 4 Way 0-10V DC Output Module DIN Rail 240V Unit L5504AMP Schneider Clipsal C-Bus Dimming Interface 4 Way 0-10V DC Output Module DIN Rail 240V Unit Product Overview The L5504AMP is a DIN rail mounted analogue output unit for the Clipsal C-Bus control ... -
B3800 Schneider Andover BACnet Field Controller Eight UI Eight DO Smart Sensor Port RS485 MS/TP Node
B3800 Schneider Andover BACnet Field Controller Product Overview The B3800 is a native BACnet field controller from the Andover Continuum b3800 series, designed as a local controller for equipment-level installation rather than head-end placement. With eight universal inputs and eight digital ... -
HD5XMSTH Schneider Duct Probe Humidity Temperature Transmitter Economy Grade 4-20mA 10k Thermistor
HD5XMSTH Schneider Duct Probe Humidity Temperature Transmitter Economy Grade 4-20mA 10k Thermistor Product Overview The HD5XMSTH is a duct-mounted temperature and humidity transmitter designed for HVAC applications. This economy grade device is ideal for volume applications where large air handling ...