SXWASB36X10001 Schneider SpaceLogic AS-B-36 Plant Room Server 36 I/O Points BACnet MS/TP Modbus RTU TCP

Product Summary
Schneider SpaceLogic AS-B-36 Plant Room Server 36 I/O Points BACnet MS/TP Modbus RTU TCP Product Overview The SXWASB36X10001 is the larger of the two SpaceLogic AS-B plant room servers, providing 36 configurable onboard I/O points compared to the 24 offered by the AS-B-24. Both devices share ...
Basic Properties
Place of Origin: EU
Brand Name: Schneider
Certification: CE RoHS
Model Number: SXWASB36X10001
Trading Properties
Minimum Order Quantity: 5
Payment Terms: T/T
Product Description
Schneider SpaceLogic AS-B-36 Plant Room Server
36 I/O Points BACnet MS/TP Modbus RTU TCP
Product Overview
The SXWASB36X10001 is the larger of the two SpaceLogic AS-B plant room servers, providing 36 configurable onboard I/O points compared to the 24 offered by the AS-B-24. Both devices share identical communication stacks, engineering workflows, enclosures, and mounting configurations. This consistency allows specifiers to size controllers to plant requirements rather than catalogue limitations, and maintenance technicians can service either unit without additional training.
The additional twelve points enable comprehensive coverage of small central plants, including extra analogue inputs for supply and return temperatures, digital inputs for pump status and flow switches, and outputs for valves and variable speed drives. The unit operates standalone, providing control and trending capabilities before head-end commissioning.
Specification Summary
Product Type Plant room automation server with onboard I/O
Order Number SXWASB36X10001
Model SpaceLogic AS-B-36
Local I/O Points 36 universal, configurable points
Network Interfaces Dual Ethernet ports with built-in switch
Protocols BACnet/IP, BACnet MS/TP and Modbus RTU/TCP
Power Supply Built-in, from mains supply within the enclosure
Platform Compatibility Same hardware architecture and software tooling as the AS-B-24
Standalone Operation Local control logic, trends and alarms without a head end
Mounting DIN rail or panel inside the plant room enclosure
Compliance CE marking; RoHS and REACH declarations held by Schneider Electric
System Integration Notes
Selection between this unit and the AS-B-24 should be based on I/O count requirements determined from detailed point schedules. Plant rooms often require more points than initially estimated when accounting for pump status, flow proving, and valve feedback. The additional twelve points enable independent wiring of critical signals, preserving diagnostic information that would be lost with shared inputs.
Network design follows the same principles as the smaller model, with built-in switching allowing controller chaining through panels and proper MS/TP segment termination. Control sequences should be designed to maintain plant safety during head-end outages, leveraging the unit's standalone capabilities.
Application Scenarios
  • Central plant rooms with multiple chillers, boilers, and associated pumps requiring interlocks between machines
  • Large air handling installations with heating/cooling coils, humidifiers, and variable speed drives needing per-device monitoring
  • Hospitals and pharmaceutical facilities requiring recorded and traceable plant status
  • District energy substations serving multiple buildings
  • Multi-phase site developments where future expansion avoids controller replacement in commissioned plant rooms
Product Details
Highlight:

Schneider SpaceLogic AS-B-36 server

,

BACnet MS/TP building controller

,

Modbus RTU TCP plant room server

Function: Control Switching Of Electrical Circuits
Inputtypes: Digital Inputs, Analog Inputs
Loadtype: Resistive And Inductive
Timer Function: Supports Scheduling And Timer Settings
Protocol: KNX Building Automation System
Protection: Electrical Isolation Between Segments

Ms. Nora

Sales Manager

Related Products