SXWASP3XX10001 Schneider SpaceLogic AS-P-3 Automation Server Premium BACnet IP BACnet SC 3 RS485 2 USB

Product Summary
SXWASP3XX10001 Schneider SpaceLogic AS-P-3 Automation Server Premium Product Overview The SXWASP3XX10001 is the Premium member of Schneider Electric's third-generation SpaceLogic automation server family. This device serves as the head end of a building management system, performing supervisory ...
Basic Properties
Place of Origin: EU
Brand Name: Schneider
Certification: CE RoHS
Model Number: SXWASP3XX10001
Trading Properties
Minimum Order Quantity: 5
Payment Terms: T/T
Product Description
SXWASP3XX10001 Schneider SpaceLogic AS-P-3 Automation Server Premium
Product Overview

The SXWASP3XX10001 is the Premium member of Schneider Electric's third-generation SpaceLogic automation server family. This device serves as the head end of a building management system, performing supervisory control logic, storing trend and alarm history, acting as a BACnet router between network segments, and publishing data to enterprise software.

Third-generation hardware adds native support for BACnet/SC, providing encrypted transport that enables building traffic over shared IT infrastructure without exposing the control network. Three RS-485 ports allow physical separation of field buses, while the Gigabit Ethernet port provides connectivity to the IT backbone with two additional Ethernet ports for local controller networks.

Specifications
Product Type Automation server, third generation, Premium tier
Order Number SXWASP3XX10001
Model SpaceLogic AS-P-3
Network Interfaces 1 x 10/100/1000 Ethernet, 2 x 10/100 Ethernet, 3 x RS-485, 2 x USB host
Protocols BACnet/IP, BACnet/SC, Modbus TCP and RTU, plus IP-based integrations
System Role Supervisory controller, BACnet router and data server
Data Management Onboard trend logs, alarm supervision and event history
Expansion Central-IO and SpaceLogic IP-IO modules over the controller network
Mounting DIN rail or panel, control room or plant room enclosure
Engineering Tool EcoStruxure Building Operation WorkStation and WebStation
Compliance CE marking; RoHS and REACH declarations held by Schneider Electric
System Integration

The AS-P-3 is typically commissioned as the root of a site, requiring coordination with IT departments for IP planning, hostname assignment, and certificate arrangements before deployment.

Best Practices: Configure BACnet/SC on both connection ends, establish routing and firewall rules early, maintain separate RS-485 buses for modern and legacy equipment, and implement documented backup strategies for control logic and database exports.
Application Scenarios
  • Large Campuses: Site server for supervisory logic, alarm management, and energy reporting across hundreds of controllers
  • Data Centers & Hospitals: Ideal for environments requiring resilience and audit trails with BACnet/SC encrypted control traffic
  • Commercial Towers: Consolidates plant room controllers, floor-level controllers, and tenant metering into unified reporting
  • Retrofit Programs: Compatible with older Schneider controllers through multiple field buses and Modbus support
  • Cloud Analytics: Standard choice for publishing building data to cloud analytics platforms
Product Details
Highlight:

Schneider SpaceLogic AS-P-3 automation server

,

BACnet IP automation server with RS485

,

Premium building controller with USB ports

Programminglanguage: Proprietary Or Standard IEC 61131-3
Special Feature: Manual Override / Local Operation
System Compatibility: KNX TP1 Standard Protocol Compatible
Rated Load Specification: 4 Channels * 250V AC / 20A
Mounting Type: DIN Rail
Application: Building Management Systems