SXWASPSBX10001 Schneider SpaceLogic AS-P-S Edge Server LonWorks FTT-10 Port 512MB RAM Security Boot

Product Summary
Schneider SpaceLogic AS-P-S Edge Server LonWorks FTT-10 Port 512MB RAM Security Boot Product Overview The SXWASPSBX10001 is the LonWorks-equipped member of the third-generation SpaceLogic automation server family, identified by Schneider Electric as the AS-P-S. It performs the same head-end duties ...
Basic Properties
Place of Origin: EU
Brand Name: Schneider
Certification: CE RoHS
Model Number: SXWASPSBX10001
Trading Properties
Minimum Order Quantity: 5
Payment Terms: T/T
Product Description
Schneider SpaceLogic AS-P-S Edge Server LonWorks FTT-10 Port 512MB RAM Security Boot
Product Overview

The SXWASPSBX10001 is the LonWorks-equipped member of the third-generation SpaceLogic automation server family, identified by Schneider Electric as the AS-P-S. It performs the same head-end duties as other Premium servers, running supervisory control logic, alarm supervision, trend logging, and BACnet routing, while adding a native LonWorks FTT-10 interface on the front of the device.

This single port makes it the standard choice for buildings with substantial installed bases of LON field devices where owners want a modern supervisory layer without replacing every controller on the trunk. Rather than purchasing separate LonWorks to BACnet gateways and treating them as integration projects, sites can present LON devices directly to the head end and map them into the same engineering database as BACnet and Modbus points.

Secure boot protects the integrity of what runs on the server, and BACnet/SC provides encrypted transport for connections traversing shared IT infrastructure, satisfying both operational and cybersecurity requirements of modern controls specifications.

Specification Summary
Product Type Automation server, Premium tier, with LonWorks interface
Order Number SXWASPSBX10001
Model SpaceLogic AS-P-S
Network Interfaces 2 x 10/100 Ethernet, 2 x RS-485, native LonWorks FTT-10
Protocols BACnet/IP, BACnet/SC, Modbus TCP and RTU, LonWorks, Zigbee where fitted
Maximum I/O Up to 464 points across 29 expansion modules
Processing ARM class processor with 512 MB RAM and 4 GB flash memory
Security Secure boot for firmware integrity, BACnet/SC encrypted transport
Supervisory Functions Control logic, alarm supervision, trend logging, protocol gateway
Mounting DIN rail, approximately 90 mm wide, 64 mm deep
Engineering Tool EcoStruxure Building Operation WorkStation and WebStation
Compliance TAA compliant; CE and RoHS declarations held by Schneider Electric
System Integration Notes

The LonWorks port changes the commissioning sequence on migration projects, as existing LON databases typically predate current team documentation. The practical approach involves:

  • Capturing the network before modification
  • Recording neuron identifiers and bindings found
  • Mapping them into the RoomLogic structure deliberately rather than relying on automatic discovery

Since the server also carries BACnet and Modbus, the same database ends up holding three device populations. Consistent naming conventions across them become crucial for maintaining a trustworthy system.

Secure boot prevents unauthorized firmware substitution, requiring planned update procedures. BACnet/SC certificate arrangements should be coordinated with IT during IP address allocation planning.

Application Scenarios

LON to BACnet Migrations: Ideal for hospitals, universities, and government estates where existing field controllers are mechanically sound but no longer supported by modern software.

Commercial Buildings: Enables mixed-vintage plant integration, bringing legacy terminal units and modern rooftop plant into one supervisory layer without complete replacement programs.

Industrial & Laboratory Facilities: Applied where Modbus equipment must be presented alongside BACnet plant.

Data Centers: Used where auditable alarm and trend history are compliance requirements.

Analytics Integration: Serves as the normalization point where three field protocols are converted into a single structured dataset for building analytics platforms.

Product Details
Highlight:

Schneider SpaceLogic AS-P-S Edge Server

,

LonWorks FTT-10 Port Edge Server

,

512MB RAM Building Controller

Programminglanguage: Proprietary Or Standard IEC 61131-3
Installation Type: Wall-mounted Or Embedded
Programming: Support For Standard Programming Languages And Graphical Configuration Tools
Protection: Electrical Isolation Between Segments
Loadtype: Resistive And Inductive