B3920 Schneider System Controller BACnet 16 Sensor Inputs 8 Triac Outputs Expansion Bus Port Smart

Product Summary
B3920 Schneider System Controller BACnet 16 Sensor Inputs 8 Triac Outputs Expansion Bus Port Smart Product Overview The B3920 is a BACnet system controller from the Andover Continuum family, designed to operate between field equipment and the head end in building management systems. It features ...
Basic Properties
Place of Origin: EU
Brand Name: Schneider
Certification: CE RoHS
Model Number: b3920
Trading Properties
Minimum Order Quantity: 5
Payment Terms: T/T
Product Description
B3920 Schneider System Controller BACnet 16 Sensor Inputs 8 Triac Outputs Expansion Bus Port Smart
Product Overview

The B3920 is a BACnet system controller from the Andover Continuum family, designed to operate between field equipment and the head end in building management systems. It features sixteen universal inputs and eight digital or analog outputs, plus a dedicated smart sensor input and expansion port for additional I/O. This configuration enables complete plant room control with a single device that can be expanded later without controller replacement.

The controller's point capacity is commercially significant, determining whether a project requires one panel or multiple units. With sixteen inputs, it can accommodate the typical mix of temperature sensors, status contacts, and flow switches found in small mechanical rooms. As a native BACnet device, it directly exposes objects to the network, supporting interoperability services for reading, trending, alarming, and scheduling without proprietary drivers.

Specification Summary
Attribute Detail
Product type BACnet system controller for building services
Order number B3920
Family Andover Continuum b3 series
Universal inputs Sixteen universal inputs for temperature sensors, contacts and analog signals
Outputs Eight digital or analog outputs; relay contacts rated for 115/230 V AC circuits
Smart sensor input One dedicated input for an Andover smart temperature sensor
Expansion Expansion port for additional I/O modules
Communication BACnet over the building network; MS/TP field bus support
Device profile BACnet Advanced Application Controller with scheduling, trending and alarm services
Engineering Programmed with the Andover Continuum engineering toolset
Mounting Panel mounted inside a grounded enclosure
Typical duty Plant room and mechanical services control with local logic execution
Compliance CE marking; RoHS and REACH declarations held by Schneider Electric
System Integration Notes

This controller level is designed to maintain operation when supervisory layers are unavailable. Control strategies should be written to maintain plant safety and functionality without network dependency.

Point allocation requires careful planning before wiring. While universal inputs are flexible, physical terminal layout must accommodate connected devices. Retrofitting incompatible sensor types is significantly more disruptive than proper initial planning.

When using the expansion port, treat additional I/O as part of the same engineering database rather than separate devices. This maintains consistent point naming and prevents conflicting plant descriptions. Application program backups should be created during commissioning and stored separately from the device.

Application Scenarios
  • Mechanical Plant Rooms: Controls pumps, valves, temperature sensors, status contacts, and interlocks for commercial building installations
  • Air Handling Systems: Manages heating/cooling coils, humidifiers, and variable speed drives with individual device monitoring
  • Infrastructure Maintenance: Used in hospitals, universities, and government facilities maintaining existing Andover Continuum systems
  • Critical Environments: Applied in data centers and laboratories requiring local logic execution and independent operation
  • Retrofit Projects: Specified for upgrades where point count and expansion capability allow enclosure and field wiring preservation
Product Details
Highlight:

Schneider BACnet system controller

,

BACnet controller 16 sensor inputs

,

Smart building controller triac outputs

Communication: KNX Bus System
Inputtypes: Digital Inputs, Analog Inputs
Input Type: Switch Input
Channel Configuration: 16 Independent Control Channels
Programming: Graphical Programming Environment