CP-LI-PR-TR-1600 Schneider CP Wet Media Pressure Transmitter 0-1600 kPa Water System Analog Output
Product Summary
CP-LI-PR-TR-1600 Schneider CP Wet Media Pressure Transmitter 0-1600 kPa Water System Analog Output The CP-LI-PR-TR-1600 is a wet media pressure transmitter from the Schneider Electric CP series, designed for permanent connection to liquid circuits. With a measuring range of 0-1600 kPa and maximum ...
Basic Properties
Place of Origin:
EU
Brand Name:
Schneider
Certification:
CE RoHS
Model Number:
CP-LI-PR-TR-1600
Trading Properties
Minimum Order Quantity:
5
Payment Terms:
T/T
Product Description
CP-LI-PR-TR-1600 Schneider CP Wet Media Pressure Transmitter 0-1600 kPa Water System Analog Output
The CP-LI-PR-TR-1600 is a wet media pressure transmitter from the Schneider Electric CP series, designed for permanent connection to liquid circuits. With a measuring range of 0-1600 kPa and maximum non-destructive pressure of 3200 kPa, this hydronic instrument features a diaphragm-separated pressure sensing element with wetted parts specifically chosen for water compatibility.
Product Overview
This transmitter is engineered for chilled water and condenser water pipework applications where readings feed plant control, pump staging, or monitoring systems. It provides a standard analog signal readable by DDC controllers on universal inputs, with an accuracy of ±0.5% of full scale suitable for system pressure monitoring.
Specifications
| Product Type | Wet media pressure transmitter for hydronic systems |
|---|---|
| Order Number | CP-LI-PR-TR-1600 |
| Series | CP series pressure transmitters |
| Media | Wet media, liquid service (chilled and condenser water) |
| Measuring Range | 0 to 1600 kPa |
| Maximum Pressure | 3200 kPa (non-destructive) |
| Accuracy | ±0.5% of full scale |
| Output Signal | Analog output selectable between 0-10 V DC and 4-20 mA |
| Output Load | ≥10 kOhm for voltage output, low impedance for current output |
| Supply | DC supply for both output types, AC supply for voltage output |
| Process Connection | Threaded connection to pipework |
| Mounting | Pipe or manifold installation at measurement point |
| Compliance | CE marking; RoHS and REACH declarations |
System Integration
Proper installation requires careful consideration of tapping point hydraulics. Avoid placements on pipe bends, at high points where air collects, or downstream of throttled valves. Ensure proper venting and correct orientation to prevent air entrapment at the diaphragm, which can cause temperature-dependent drift.
Important: Match output type to controller input and verify scaling corresponds to the device's actual range. Installation of isolation valves enables transmitter removal without circuit drainage.
Applications
- Chilled water and condenser water distribution systems
- Differential pressure monitoring across pumps and terminal branches
- Pump staging sequences for mechanical fault detection
- District cooling substations and central plant rooms
- Building management system dashboards and energy reporting
- Water treatment and filtration system maintenance monitoring
Product Details
Highlight:
Schneider CP water pressure transmitter
,wet media pressure sensor 1600 kPa
,analog output water system transmitter
Loadtype:
Resistive And Inductive
Wiring Device Mounting:
DIN Rail
Operating Temperature:
-10°C To 50°C
Installation:
TH35 DIN Rail Mounting
Installation Type:
Wall-mounted Or Embedded
Product Series:
Schneide SpaceLogic KNX Series
Related Products
-
HR3001EC Schneider HR3000 Guest Room Expansion Module Additional IO Points and Control Loops Expansion Unit
HR3001EC Schneider HR3000 Guest Room Expansion Module Additional IO Points and Control Loops Expansion Unit Product Overview The HR3001EC expansion module extends the capacity of the HR3000 guest room control system. While the main module defines room functionality, the expansion module determines ... -
Schneider BACnet Direct Digital Controller b3624 Building Automation New
Schneider BACnet Direct Digital Controller b3624 Building Automation New The Schneider Electric BACnet Direct Digital Controller b3624 is a mid-range freely programmable BACnet controller with 24 I/O points, designed for AHU control, FCU supervision, and medium-complexity HVAC applications in ... -
MTN432119 Schneider Merten System M Rocker Polar White Glossy Single Switch Cover Plate Accessory
MTN432119 Schneider Merten System M Rocker Polar White Glossy Single Switch Cover Plate Accessory Product Overview The Schneider Electric MTN432119 is a premium building automation component designed for high-performance integration within the modern smart building ecosystem. Engineered to deliver ...