HR3002CN Schneider HR3000 Guest Room 2 Way Curtain Module for Electric Curtains and Blinds Control Unit
The HR3002CN is a two-way curtain module designed for the HR3000 guest room control system, specifically engineered to drive motorized window treatments. This module features two output channels that correspond to the wiring requirements of curtain and blind motors—each motor requires separate live conductors for opening and closing directions.
The module provides essential changeover functionality and includes an interlock mechanism that prevents both directions from being energized simultaneously. In hotel guest rooms, automated window treatments contribute significantly to room presentation and thermal management, enhancing guest experience by coordinating curtain operation with room scenes.
Designed for short pulse control compatible with motorized curtains, the HR3002CN integrates seamlessly with the HR3000 system architecture, receiving commands from the main module via the module bus alongside lighting controls.
| Feature | Description |
|---|---|
| Product Type | Two-way module for motorized curtain and blind control |
| Order Number | HR3002CN |
| Series | HR3000 guest room control system |
| Channels | Two output channels, one per direction of travel |
| Interlock | Prevents simultaneous energization of both directions |
| Typical Loads | Electric curtains, roller blinds, venetian or solar shading motors |
| Control Mode | Short pulse or timed operation matched to motor requirements |
| Module Supply | 12 V DC module bus |
| Supply Units | Fed from HR3001PM main supply or HR3002PE expansion supply |
| Control | Commands received from HR3001MC main module over module bus |
| Integration | Integrated with room scenes and bedside/entrance controls |
| Mounting | Installed inside room control enclosure |
| Compliance | CE marking; RoHS and REACH declarations held by Schneider Electric |
- Motor stopping mechanism (internal limit switch vs. controller power removal)
- Control method (short pulse vs. continuous drive requirements)
- Module behavior when receiving commands during active curtain movement
Improper configuration can lead to motor damage—for example, continuous drive on a pulse-controlled motor causes stalling and persistent humming. Commissioning should include verification of travel direction for each window, as reversed operation is a common guest complaint. The interlock function provides essential protection and should be verified during installation.
The HR3002CN is primarily deployed in hotel guest rooms where automated window treatments enhance room functionality and guest comfort. Key applications include:
- Hotel suites with multiple windows requiring coordinated control
- Resort properties utilizing solar shading for thermal management
- Executive floors and club rooms with enhanced room specifications
- Serviced apartments and branded residences with standard motorized blinds
- Conference and meeting rooms requiring blackout capabilities for presentations
The module is typically installed alongside lighting controls in the same enclosure, enabling unified management of both natural and artificial lighting within the room environment.
Schneider HR3000 curtain control module
,2 way electric curtain module
,guest room blinds control unit
-
Schneider BACnet Direct Digital Controller b3624 Building Automation New
Schneider BACnet Direct Digital Controller b3624 Building Automation New The Schneider Electric BACnet Direct Digital Controller b3624 is a mid-range freely programmable BACnet controller with 24 I/O points, designed for AHU control, FCU supervision, and medium-complexity HVAC applications in ... -
MNL-V1RV3-2 Schneider TAC I/A MicroNet LonWorks VAV Terminal Box Controller Integral Actuator 12VA
MNL-V1RV3-2 Schneider TAC I/A MicroNet LonWorks VAV Terminal Box Controller Integral Actuator 12VA MNL-V1RV3-2 Schneider TAC I/A MicroNet LonWorks VAV Terminal Box Controller Integral Actuator 12VA Product Overview The MNL-V1RV3-2 is a LonMark VAV terminal box controller from the TAC I/A Series ... -
SE8350U0B11 Schneider SE8000 Low Voltage Fan Coil and Zone Room Controller BACnet MS/TP RH Sensor White
SE8350U0B11 Schneider SE8000 Low Voltage Fan Coil and Zone Room Controller BACnet MS/TP RH Sensor White The SE8350U0B11 is a low-voltage fan coil room and zone controller from the Schneider Electric SE8000 range, designed to bridge the gap between mechanical thermostats and full building management ...