STD100-100 Schneider Duct Temperature Sensor 100mm Probe NTC 1.8k Ohm IP65 Air Duct Mounting Sensor

Product Summary
STD100-100 Schneider Duct Temperature Sensor 100mm Probe NTC 1.8k Ohm IP65 Air Duct Mounting Sensor Product Overview The STD100-100 is a duct-mounted temperature sensor from Schneider Electric's STD range, featuring a 100mm probe with an NTC 1.8 kilo-ohm sensing element. Designed specifically for ...
Basic Properties
Place of Origin: EU
Brand Name: Schneider
Certification: CE RoHS
Model Number: STD100-100
Trading Properties
Minimum Order Quantity: 5
Payment Terms: T/T
Product Description
STD100-100 Schneider Duct Temperature Sensor 100mm Probe NTC 1.8k Ohm IP65 Air Duct Mounting Sensor
Product Overview

The STD100-100 is a duct-mounted temperature sensor from Schneider Electric's STD range, featuring a 100mm probe with an NTC 1.8 kilo-ohm sensing element. Designed specifically for measuring air temperature inside ducts, this sensor provides critical data for HVAC system performance monitoring and control decisions.

Unlike room temperature measurements, duct temperature readings inform key system operations: air leaving cooling coils indicates coil performance, mixed air chamber temperatures determine damper positions, and supply duct temperatures after reheat coils confirm heater operation. The 100mm probe length ensures representative readings by reaching beyond boundary layers near duct walls to measure the actual moving air stream.

Technical Specifications
Product Type Duct mounted temperature sensor
Order Number STD100-100
Series STD duct temperature sensors
Sensing Element NTC 1.8 kilo-ohm thermistor
Probe Length 100 mm
Mounting Dct mounting, probe inserted through duct wall
Ingress Protection IP65
Housing Connection box with 20 mm cable cut out and 20 mm conduit gland
Materials Stainless steel probe tube, polyamide connection box
Measurement Accuracy Approximately ±0.3°C over 0 to 25°C range
Compatible Systems Schneider building controllers supporting 1.8 kilo-ohm element
Measured Medium Air in supply, return, mixed air and exhaust ducts
Typical Application Air handling unit and duct temperature measurement
Compliance CE marking; RoHS and REACH declarations held by Schneider Electric
System Integration

Proper sensor placement is critical for accurate measurements. Probe length and air stratification considerations ensure the sensing element measures representative duct air rather than boundary layers near walls or unmixed air streams.

Important Installation Notes: Avoid positions immediately after coils, fan discharges, or dampers where air streams may not be fully mixed. Moving measurement points upstream or downstream is often more effective than changing sensors. Controller inputs must be configured for the 1.8 kilo-ohm characteristic curve—mismatched configurations produce stable but incorrect readings that are difficult to detect.

Ensure proper gland and housing sealing during installation. Leaky duct penetrations can admit dust and moisture, compromising sensor longevity and performance.

Application Scenarios
  • Air Handling Units: Verify coil performance and control heating/cooling stages
  • Mixed Air & Economiser Control: Determine outdoor and return air proportions
  • Reheat Applications: Confirm delivered supply air conditions
  • Extract Air Monitoring: Establish plant load from occupied spaces
  • Laboratories & Cleanrooms: Validate installed air system performance
  • Retrofit Projects: Utilize existing duct penetrations with compatible probe
Product Details
Highlight:

Schneider duct temperature sensor 100mm probe

,

NTC 1.8k Ohm air duct sensor

,

IP65 duct mounting temperature sensor

Inputtype: Binary Switch Input
Function: Control Electrical Switches Remotely
Type: Electrical Switch Actuator
Outputsignal: Analog Voltage
Load Capacity: Supports Motors Up To 100W

Ms. Nora

Sales Manager

Related Products
Send An Inquiry