STD100-100 Schneider Duct Temperature Sensor 100mm Probe NTC 1.8k Ohm IP65 Air Duct Mounting Sensor
The STD100-100 is a duct-mounted temperature sensor from Schneider Electric's STD range, featuring a 100mm probe with an NTC 1.8 kilo-ohm sensing element. Designed specifically for measuring air temperature inside ducts, this sensor provides critical data for HVAC system performance monitoring and control decisions.
Unlike room temperature measurements, duct temperature readings inform key system operations: air leaving cooling coils indicates coil performance, mixed air chamber temperatures determine damper positions, and supply duct temperatures after reheat coils confirm heater operation. The 100mm probe length ensures representative readings by reaching beyond boundary layers near duct walls to measure the actual moving air stream.
| Product Type | Duct mounted temperature sensor |
| Order Number | STD100-100 |
| Series | STD duct temperature sensors |
| Sensing Element | NTC 1.8 kilo-ohm thermistor |
| Probe Length | 100 mm |
| Mounting | Dct mounting, probe inserted through duct wall |
| Ingress Protection | IP65 |
| Housing | Connection box with 20 mm cable cut out and 20 mm conduit gland |
| Materials | Stainless steel probe tube, polyamide connection box |
| Measurement Accuracy | Approximately ±0.3°C over 0 to 25°C range |
| Compatible Systems | Schneider building controllers supporting 1.8 kilo-ohm element |
| Measured Medium | Air in supply, return, mixed air and exhaust ducts |
| Typical Application | Air handling unit and duct temperature measurement |
| Compliance | CE marking; RoHS and REACH declarations held by Schneider Electric |
Proper sensor placement is critical for accurate measurements. Probe length and air stratification considerations ensure the sensing element measures representative duct air rather than boundary layers near walls or unmixed air streams.
Ensure proper gland and housing sealing during installation. Leaky duct penetrations can admit dust and moisture, compromising sensor longevity and performance.
- Air Handling Units: Verify coil performance and control heating/cooling stages
- Mixed Air & Economiser Control: Determine outdoor and return air proportions
- Reheat Applications: Confirm delivered supply air conditions
- Extract Air Monitoring: Establish plant load from occupied spaces
- Laboratories & Cleanrooms: Validate installed air system performance
- Retrofit Projects: Utilize existing duct penetrations with compatible probe
Schneider duct temperature sensor 100mm probe
,NTC 1.8k Ohm air duct sensor
,IP65 duct mounting temperature sensor
-
L5504AMP Schneider Clipsal C-Bus Dimming Interface 4 Way 0-10V DC Output Module DIN Rail 240V Unit
L5504AMP Schneider Clipsal C-Bus Dimming Interface 4 Way 0-10V DC Output Module DIN Rail 240V Unit L5504AMP Schneider Clipsal C-Bus Dimming Interface 4 Way 0-10V DC Output Module DIN Rail 240V Unit Product Overview The L5504AMP is a DIN rail mounted analogue output unit for the Clipsal C-Bus control ... -
B3624 Schneider BACnet Local Controller 24 Universal Inputs Line Fault Monitoring DIN Rail IP20 DDC
B3624 Schneider BACnet Local Controller BACnet Local Controller with 24 Universal Inputs, Line Fault Monitoring, DIN Rail Mount, IP20 Rating, DDC Product Overview The B3624 is a local controller from the Andover Continuum b3600 series, featuring twenty-four universal inputs in a single enclosure. ... -
SXWRCF12B10001 Schneider SmartX RP-C Room Controller 12 Point 8 Universal IO Fan Coil BACnet IP Dual
SXWRCF12B10001 Schneider SmartX RP-C Room Controller Product Overview The SXWRCF12B10001 is a SmartX IP room controller from the SpaceLogic RP-C family, designed to bridge the gap between stand-alone thermostats and full direct digital control installations. This advanced controller features twelve ...