N 141/21 5WG1141-1AB21 KNX DALI Gateway Twin Plus 2 Lines DALI Sensors Emergency Test Log
Product Summary
N 141/21 5WG1141-1AB21 KNX DALI Gateway Twin Plus 2 Lines DALI Sensors Emergency Test Log Product Overview The N141/21 carries the plus label, representing a two-line gateway with a comprehensive function library essential for regulated lighting projects. This device operates two independent DALI ...
Basic Properties
Certification:
CE
Model Number:
N 141/21
Trading Properties
Minimum Order Quantity:
5
Payment Terms:
T/T
Product Description
N 141/21 5WG1141-1AB21 KNX DALI Gateway Twin Plus 2 Lines DALI Sensors Emergency Test Log
Product Overview
The N141/21 carries the plus label, representing a two-line gateway with a comprehensive function library essential for regulated lighting projects. This device operates two independent DALI lines, supports selected DALI sensors on either line, and enables operation, testing, and documentation of emergency luminaires. Engineering is performed from ETS using application number 983411.
Technical Specifications
| Protocol & Capacity | KNX TP1 device with two separate DALI interfaces to IEC 60929. Each line addresses up to 64 DALI actuators plus at least ten additional sensors per channel. DALI-2 certified for devices with DALI-2 logo. |
|---|---|
| Power Supply | Internal power supply generates DALI bus voltage and feeds the gateway. Ballasts and sensors draw energy from the gateway, eliminating need for secondary DALI supply. Front key enables direct mode for switching and dimming without KNX traffic. |
| Sensor Support | Supports DALI pushbutton couplers and DALI presence/brightness sensors. Each channel accepts up to sixteen pushbutton inputs and eight presence detectors, all parameterized in ETS project. |
| Emergency Lighting | Emergency mode activates when configurable number of DALI ballasts stop responding. Logs emergency lighting test results. Inhibit mode prevents battery operation during normal conditions. Lock object suppresses failure messages during testing. |
Lighting Control Features
- Closed-loop constant light control
- Two-point light control
- One- and two-level timer operation
- Effect control and dimming value limits
- Conversion of dimming commands to temporary setpoint changes
- Sixteen scenes per channel
- Burn-in for entire system or triggered by object
- Pre-loaded applications
- Color temperature control (firmware V11+)
Diagnostics & Maintenance
Provides group and device level status and fault messages including DALI device failure, supply failure, and DALI short circuit. Defective ballasts can be replaced without software - gateway automatically writes configuration to new devices of same type.
Operating Modes & Mechanics
Bus, broadcast, standalone, direct, and constant-light modes. Rail-mounted housing for distribution boards. Integrated bus coupling unit draws only half standard bus load. Requires ETS 5 or above with firmware V15 for parameterization. Configuration data importable from other KNX/DALI gateways.
Application Scenarios
Ideal for applications requiring verifiable lighting systems: hospitals, care homes, universities, schools, office buildings, shopping centers, railway stations, airports, and cultural venues. Sensor support benefits refurbishment projects, while software-free ballast replacement ensures predictable maintenance in publicly accessible buildings.
Product Details
Highlight:
KNX DALI Gateway Twin Plus
,DALI Sensors Emergency Test
,Dimming Actuator with warranty
Bus Protocol:
KNX Open Bus Protocol
Controlmethod:
Electrical And Manual Override
Power Supply Mode:
KNX Bus Power Supply (DC 24V)
Number Of Throws:
Single Throw / Double Throw
Maxload:
300W Per Channel
Output Channels:
2 Independent Dimming Channels
Power Consumption:
Approximately 10mA
Related Products
-
NP16163_01BK_E1 Schneider Unica KNX Six Gang Push Button Black Backlit Symbols Programmable Module
Product Overview The NP16163_01BK_E1 is a six-key Unica KNX push button finished in black — the key count that most often marks the boundary between a room control and a small scene controller. Six keys on a single 86 mm plate allow lighting, curtains and several scenes to be addressed separately. ... -
LF/U 2.1 ABB i-bus KNX Flush Mount Light Sensor 200-3000 lx Brightness Probe for Constant Light Control
LF/U 2.1 ABB i-bus KNX Flush Mount Light Sensor 200-3000 lx Brightness Probe for Constant Light Control Product Overview The LF/U 2.1 ABB i-bus KNX flush-mounted light sensor provides brightness measurement for constant lighting control. It measures illuminance in the room and transmits values to ... -
AA/S 4.1.2 ABB i-bus KNX 4-Channel Analogue Output Module DIN Rail 0-10V / 0(4)-20mA for Valve Control
AA/S 4.1.2 ABB i-bus KNX 4-Channel Analogue Output Module The ABB i-bus KNX AA/S 4.1.2 is a four-channel analogue output module for modular DIN-rail installation. Its task is to translate bus telegrams into continuous electrical signals, bridging the KNX installation and third-party HVAC equipment ...