Schneider MTN6720-0008 SpaceLogic KNX 8-Channel 1-10V Dimming Actuator
2026/03/19
| Category | Specification Item | Detailed Parameters & Functional Description |
|---|---|---|
| Basic Core Attributes | Brand | Schneider Electric |
| Model Number | MTN6720-0008 | |
| Product Series | SpaceLogic KNX | |
| Product Type | 1-10V Dimming Actuator | |
| Active Operation | Dimmer | |
| Operation Mode | KNX Bus System, Manual Override | |
| Bus/Network Type | KNX (KNX DataSecure Certified) | |
| Number of Outputs | 8 Channels | |
| Local Signalling | LED Indicators: Yellow (ON/OFF), Red (Programming Mode), Green (Application Download) | |
| Colour | White | |
| Topology | TP1-256 | |
| Electrical Performance Parameters | Rated Operating Voltage [Ue] | 220...240 V AC |
| Mains Frequency | 50/60 Hz | |
| Rated Current [In] | 16 A (20A AC1 Relay per Channel) | |
| Power Consumption | 600 mW (KNX Device) | |
| Input Current Limit | 12…23 mA at 24 V DC (KNX Device) | |
| Power Factor | ≤0.6 | |
| Analog Output Type | Voltage | |
| Analog Output Range | 1...10 V DC (Sinking Current Max 100mA) | |
| Load Rating (Per Channel) | Incandescent Lamp: 3680 W at 220...240 V 50/60 Hz ACLV Halogen Lamp (Conventional Transformer): 2200 VA at 220...240 V 50/60 Hz ACLV Halogen Lamp (Electronic Ballast): 3000 VA at 220...240 V 50/60 Hz ACFluorescent Lamp (Conventional Ballast): 3680 W at 220...240 V 50/60 Hz ACLED Optimized: 650W (PF>0.6), 300W (PF=0.5-0.6) | |
| Mechanical & Installation Data | Wiring Capacity | Overload: Screw Terminal for 32 Cables; KNX Bus: Bus Terminal |
| Tightening Torque | 0.8 N.m (Load Terminal); 0.5 N.m (Output Terminal) | |
| Configuration | Programmable via ETS Software (Dimming Curve, Speed, Memory, Delay, Staircase Lighting Control) | |
| Installation Method | DIN Rail Mounting (TH35, EN 60715 Standard) | |
| Total 18mm Modules | 4 | |
| Product Dimensions (W*H*D) | 144 mm * 90 mm * 65.7 mm | |
| Environmental & Compliance | IP Rating | IP20 |
| Operating Temperature | -5…45 °C | |
| Storage Temperature | -25…55 °C | |
| Transport Temperature | -25…70 °C | |
| Relative Humidity | 0…93 % Non-Condensing | |
| Operating Altitude | < 2000 m | |
| Pollution Degree | 2 | |
| Safety Class | Category 2 (Class II Insulation) | |
| Overvoltage Category | III | |
| Certifications | CE, KNX, IEC CB Report | |
| Packaging Specifications | Package 1 (PCE) | 1 Unit; 9.6 cm * 12.6 cm * 15.8 cm; 697 g |
| Package 2 (CAR) | 10 Units; 21 cm * 29.8 cm * 39.8 cm; 7.47 kg (Gross Weight) | |
| Package 3 (P06) | 160 Units; 105 cm * 60 cm * 80 cm; 129.52 kg (Gross Weight) | |
| Warranty Terms | Contractual Warranty Period | 18 Months |