HR3001FC Schneider HR3000 Guest Room Air Conditioning Control Module Fan Coil Terminal Logic Control Unit
Product Summary
HR3001FC Schneider HR3000 Guest Room Air Conditioning Control Module Fan Coil Terminal Logic Control Unit The HR3001FC is the air conditioning control module of the HR3000 guest room control system, designed to integrate the room's terminal unit with the same behavioral patterns as its lighting ...
Basic Properties
Place of Origin:
EU
Brand Name:
Schneider
Certification:
CE RoHS
Model Number:
HR3001FC
Trading Properties
Minimum Order Quantity:
5
Payment Terms:
T/T
Product Description
HR3001FC Schneider HR3000 Guest Room Air Conditioning Control Module Fan Coil Terminal Logic Control Unit
The HR3001FC is the air conditioning control module of the HR3000 guest room control system, designed to integrate the room's terminal unit with the same behavioral patterns as its lighting system.
Product Overview
In guest rooms, air conditioning typically represents the largest single energy consumer and is often left running in unoccupied rooms. By integrating with the room controller, this module enables significant energy savings: the fan coil can be set back when the room is unoccupied, restored when a key card is inserted, and driven to comfortable conditions as part of a welcome scene. The module provides the logic and outputs to drive the terminal unit—controlling fan speeds, water valves, and room temperature sensing according to the installed unit's requirements. As part of the same architecture as the lighting system, the room presents unified behavior to guests rather than operating as multiple independent systems.
Specification Summary
- Product Type: Air conditioning control module for guest room terminal unit
- Order Number: HR3001FC
- Series: HR3000 guest room control system
- Function: Logic control of room fan coil or air conditioning terminal unit
- Controlled Elements: Fan speeds and water valve outputs appropriate to terminal unit
- Room Integration: Fan and valve behavior tied to room occupancy state and scene selection
- Module Supply: DC 12V from main module supply
- Supply Units: Fed from HR3001PM main supply or HR3002PE expansion supply
- Control: Commands received from HR3001MC main module over module bus
- Energy Behavior: Setback of terminal unit when room is unoccupied
- Guest Interface: Temperature control presented through room's thermostat and panels
- Mounting: Installed inside room control enclosure
- Compliance: CE marking; RoHS and REACH declarations held by Schneider Electric
System Integration Notes
Integrating air conditioning with the room controller changes commissioning procedures, as temperature behavior and occupancy logic must be coordinated rather than handled separately. Operational policies—such as fan behavior when guests remove key cards, restoration speed on check-in, and guest override permissions—are typically defined by hotel operators. The controller must be capable of implementing these policies without compromise. The interface to the terminal unit must match the installed equipment, accounting for differences in fan speeds, valve outputs, and pipe arrangements. Room temperature sensing for control loops should be placed within the space rather than inside the controller enclosure to ensure accurate environmental measurement.
Application Scenarios
Hotel Guest Rooms: Primary application where air conditioning integrates with occupancy for comfort and energy efficiency.
Resorts in Warm Climates: Used where cooling dominates energy load and setback behavior directly impacts operating costs.
City Hotels: Applied where rooms remain unoccupied for significant portions of the day.
Serviced Apartments & Branded Residences: Specified where heating and cooling are integrated into room control systems.
Refurbishment Projects: Added to retain existing terminal units while moving control from local thermostats to room controllers.
Integrated Systems: Frequently specified alongside lighting modules to enable single-guest gestures or scenes that simultaneously adjust lighting, temperature, and curtains.
Resorts in Warm Climates: Used where cooling dominates energy load and setback behavior directly impacts operating costs.
City Hotels: Applied where rooms remain unoccupied for significant portions of the day.
Serviced Apartments & Branded Residences: Specified where heating and cooling are integrated into room control systems.
Refurbishment Projects: Added to retain existing terminal units while moving control from local thermostats to room controllers.
Integrated Systems: Frequently specified alongside lighting modules to enable single-guest gestures or scenes that simultaneously adjust lighting, temperature, and curtains.
Key Benefit: Delivers significant energy savings by integrating air conditioning control with room occupancy, providing unified system behavior while maintaining guest comfort.
Product Details
Highlight:
Schneider HR3000 fan coil control module
,guest room air conditioning logic control
,HR3001FC terminal control unit with warranty
Related Products
-
L5504AMP - C-Bus 4-Channel Analogue Output Unit, 0-10V DC DIN Rail Mount for LED Ballasts
L5504AMP - C-Bus 4-Channel Analogue Output Unit, 0-10V DC DIN Rail Mount for LED Ballasts The L5504AMP is a C-Bus 4-channel analogue output module that provides a 0-10V DC variable voltage output proportional to C-Bus network commands. Designed specifically for controlling electronic ballasts and ... -
CP-LI-PR-TR-1600 Schneider CP Wet Media Pressure Transmitter 0-1600 kPa Water System Analog Output
CP-LI-PR-TR-1600 Schneider CP Wet Media Pressure Transmitter 0-1600 kPa Water System Analog Output The CP-LI-PR-TR-1600 is a wet media pressure transmitter from the Schneider Electric CP series, designed for permanent connection to liquid circuits. With a measuring range of 0-1600 kPa and maximum ... -
L5508D1AP Schneider Clipsal C-Bus 8 Channel 1A Leading Edge Dimmer DIN Rail 240V Without Power Supply
L5508D1AP Schneider Clipsal C-Bus 8 Channel 1A Leading Edge Dimmer DIN Rail 240V Without Power Supply Product Overview The L5508D1AP is a DIN rail mounted leading edge dimmer from the Clipsal C-Bus range, configured with eight independent channels at 1 A each. The trailing P in the part number ...