N 141/31 5WG1141-1AB31 KNX DALI Gateway Twin 2 Lines 128 Ballasts 32 Groups Stand Alone

Product Summary
N 141/31 5WG1141-1AB31 KNX DALI Gateway Twin 2 Lines 128 Ballasts 32 Groups Stand Alone Product Overview The N141/31 is the basic twin model in the KNX/DALI family, serving as an entry point for projects requiring two DALI lines at moderate cost. This gateway efficiently brings large numbers of ...
Basic Properties
Certification: CE
Model Number: N 141/31
Trading Properties
Minimum Order Quantity: 5
Payment Terms: T/T
Product Description
N 141/31 5WG1141-1AB31 KNX DALI Gateway Twin 2 Lines 128 Ballasts 32 Groups Stand Alone
Product Overview

The N141/31 is the basic twin model in the KNX/DALI family, serving as an entry point for projects requiring two DALI lines at moderate cost. This gateway efficiently brings large numbers of digital ballasts under KNX control, organizes them into groups, drives them through scenes, and maintains lighting operation when the automation network is unavailable.

Technical Specifications
Protocol & Addressing KNX TP1 device with two DALI interfaces to IEC 60929
Each interface supports up to 64 DALI ballasts
Maximum 128 ballasts across both lines
Up to 32 DALI groups
Status and lamp-failure feedback per group and device
Power Supply 110-240 V AC, 50/60 Hz or 120-240 V DC
DALI bus voltage: maximum 19 V, short-circuit proof
Powers connected DALI sensors
Additional DALI supply not required or permitted
Local Interface LC display for operating mode and error text
One key toggles between bus and direct mode
Two keys for switching all ballasts on/off
Individual status LED for each DALI output
Functions & Operation Broadcast operation for entire lines
Group control with switching and dimming
16 two-level controllers for brightness-dependent switching
Timer functions (one- or two-level)
32 scene control capability
Stand-alone operation during KNX communication failure
Engineering & Mechanical ETS plug-in with table-oriented parameter view
Customizable columns with sorting and filtering
Configuration stored in ETS project
Import function for data from other KNX/DALI gateways
Requires ETS 5 or above with firmware V15
4 module widths (72 mm) on DIN rail EN 60715-TH35-7.5
Weight: approximately 0.47 kg
Firmware Scope (V15)

Compared to plus models, this device omits:

  • DALI sensor and input-device support
  • Emergency lighting test logging
  • Constant-light and two-point control
  • Timer/effect blocks and pre-loaded applications

Broadcast, group, scene, and stand-alone operation remain fully available.

DALI-2 certificate valid where DALI-2 logo appears on device label.

Application Scenarios

Ideal for office buildings, hotels, shopping centers, airports, and campus buildings where luminaires require individual addressing but primarily group control. The 32 groups effectively separate work zones in planning offices and multipurpose halls. The autonomous operation capability makes it suitable for areas where lighting must remain operational during KNX network maintenance.

Product Details
Highlight:

KNX DALI Gateway Twin 2 Lines

,

DALI Gateway 128 Ballasts

,

KNX dimming actuator 32 groups

Inputtype: Binary Input
Protection: Electrical Isolation Between Segments
Control Type: Remote And Manual Control
Loadtype: Incandescent Lamps, LED Lamps, Fluorescent Lamps
Installation: Flush Mounted
Product Type: Hybrid Switch Actuator
Function: Light Dimming Control