R9MCT160 Schneider Resi9 Current Transformer Kit 160A Three Pieces Energy Meter Modbus CT Cabinet Set

Product Summary
Product Overview The R9MCT160 is the mid-range current transformer in the Schneider Resi9 range, rated at 160 amperes and supplied as a set of three — the quantity required for a three-phase circuit. Its defining dimension is the 18.5 mm conductor opening, which allows it to close around a feeder ...
Basic Properties
Place of Origin: EU
Brand Name: Schneider
Certification: CE RoHS
Model Number: R9MCT160
Trading Properties
Minimum Order Quantity: 5
Payment Terms: T/T
Product Description
Product Overview

The R9MCT160 is the mid-range current transformer in the Schneider Resi9 range, rated at 160 amperes and supplied as a set of three — the quantity required for a three-phase circuit. Its defining dimension is the 18.5 mm conductor opening, which allows it to close around a feeder that would not pass through the 80 A version. This is the number to check against the cable schedule before the board is built, not after.

The 1.5 m signal lead in a single pair is long enough to reach the meter from the bottom of a board where the transformers sit on the outgoing side. The 54 * 48 * 29 mm body is compact enough to fit beside a breaker without consuming a way.

Specification Summary
Catalogue reference R9MCT160
Range Resi9, Resi9 CT
Device type Current transformer for energy metering
Maximum current 160 A
Quantity in set Three transformers
Largest conductor accepted 18.5 mm diameter
Signal lead length 1.5 m, one pair
Compatibility Resi9 and PowerTag energy meters, including the universal meter
Product use Universal metering inside a distribution board
Dimensions 54 mm high * 48 mm wide * 29 mm deep
Front colour Green, Pantone 355C
Body colour White RAL 9003
Carbon footprint 74 kg CO₂ equivalent (33 kg manufacturing, 39 kg use phase)
Recyclability potential 11%
Take back Covered by a take back scheme
System Integration Notes

This transformer belongs with the universal meter rather than the fixed single-phase unit, because the 160 A range is one of the three configurations the universal meter accepts — and the meter must be set to the transformer that is actually fitted. The consequences of a mismatch are systematic rather than random: every current and power reading scales by the ratio between the assumed and the real transformer, so the energy total drifts by the same factor and the error looks like a calibration problem rather than a selection problem.

Two further points belong in the installation note. First, the transformer is directional in the sense that the conductor must pass through the core alone, with no return conductor and no parallel feed inside the window. Second, the 160 A rating is a saturation limit, so a circuit expected to run near it continuously should be measured with the 250 A version instead.

Three pieces per set means one set per three-phase circuit, not per phase.

Application Scenarios

The 160 A transformer is specified on the feeders of small commercial boards rather than on final circuits. Heat pumps, small chillers, workshop sub-mains and the incoming tails of a shop unit all fall into the range where 80 A is too close to the working current and 250 A is unnecessary — and the 18.5 mm opening is the practical check that decides it.

Offices apply it to the sub-main that feeds a floor, so that the floor can be compared with its own sub-meters. Retail chains use it where a store has a three-phase intake and consumption has to be benchmarked against other stores of the same format. In a board that already has an 80 A set on the final circuits, the 160 A set on the sub-main completes the picture without changing the meter — which is the argument for a universal device in the first place.

Product Details
Highlight:

Resi9 160A current transformer kit

,

Modbus energy meter CT set

,

Schneider three-piece CT cabinet