Building Automation Components
Schneider Liquid Differential Pressure Sensor 0-689kPa 0-10V EPW104 New
Schneider Liquid Differential Pressure Sensor 0-689kPa 0-10V EPW104 New The Schneider Electric Liquid Differential Pressure Sensor EPW104 measures 0-689 kPa (0-100 psi) differential pressure in hydronic HVAC piping, providing a 0-10V output for pump head monitoring, control valve differential pressure, and flow measurement calculations. Key Specifications Part Number EPW104 Measurement Range 0 to 689 kPa (0 to 100 psi) Output Signal 0-10V DC Media Water, glycol solutions
Schneider Duct Differential Pressure Sensor 0-2500Pa 0-10V EPD302 New
Schneider Duct Differential Pressure Sensor 0-2500Pa 0-10V EPD302 New Product Overview The Schneider Electric Duct Differential Pressure Sensor EPD302 measures 0-2500 Pa differential pressure with a 0-10V output, purpose-built for high-pressure duct monitoring, filter banks, heat recovery units, and VAV system static pressure control in commercial HVAC applications. Technical Specifications Specification Details Part Number EPD302 Measurement Range 0 to 2500 Pa Output Signal
Schneider Liquid Differential Pressure Sensor EPW105 Brand New Original
Schneider Liquid Differential Pressure Sensor EPW105 The Schneider Electric Liquid Differential Pressure Sensor EPW105 is a hydronic-grade differential pressure transmitter designed for chilled water, hot water, and condenser water HVAC systems. This brand new, original product provides reliable analogue output for pump differential pressure control and hydronic balancing. Key Specifications Part Number EPW105 Output Signal Analogue (0-10V or 4-20mA, model dependent) Media
Schneider Outdoor Humidity Temp Sensor 3% 0-10V 10K Ohm HO3XVSTH New
Schneider Outdoor Humidity Temp Sensor 3% 0-10V 10K Ohm HO3XVSTH The Schneider Electric Outdoor Humidity and Temperature Sensor (Part No. HO3XVSTH) delivers high-accuracy outdoor measurement with ±3% RH humidity output (0-5V/0-10V) and 10K Ohm Type 3 NTC temperature resistance. Designed for demanding building energy management and HVAC weather compensation applications. Key Specifications Part Number: HO3XVSTH Humidity Output: 0-5V or 0-10V (selectable), ±3% RH accuracy, 0
Schneider Duct Humidity Temp Sensor 4-20mA 1.8K Ohm HD5XMSTN Brand New
Schneider Duct Humidity Temp Sensor 4-20mA 1.8K Ohm HD5XMSTN Product Overview The Schneider Electric Duct Humidity and Temperature Sensor (Part No. HD5XMSTN) provides simultaneous humidity and temperature measurement in HVAC air ducts. This brand new, original Schneider Electric product supports precise supply air conditioning and IAQ (Indoor Air Quality) control with reliable performance. Technical Specifications Part Number HD5XMSTN Humidity Output 4-20mA, accuracy ±5% RH
Schneider Indoor Temperature Humidity Sensor HEW3VSTH Brand New Original
Schneider Indoor Temperature Humidity Sensor HEW3VSTH Product Overview The Schneider Electric Indoor Temperature and Humidity Sensor (Part No. HEW3VSTH) is a brand new, original wall-mount combined sensor delivering dual analogue outputs for room temperature and relative humidity. Designed for BAS integration in commercial comfort and IAQ monitoring applications. Technical Specifications Part Number HEW3VSTH Temperature Output Passive NTC resistance or 0-10V (model dependent)
Schneider Brass Thermowell PN16 50mm 9121040000 Brand New Original
Schneider Brass Thermowell PN16 50mm 9121040000 Brand New Original The Schneider Electric Brass Thermowell (Part No. 9121040000) is a PN16-rated 50mm brass immersion sleeve designed to protect pipe temperature sensor probes from direct fluid contact, enabling in-service sensor removal and replacement without system shutdown. Key Specifications Part Number 9121040000 Material Brass Pressure Rating PN16 (16 bar) Insertion Length 50 mm Thread Connection BSP/NPT (standard)
Schneider Brass Thermowell PN16 100mm 9121041000 Brand New Original
Schneider Brass Thermowell PN16 100mm 9121041000 The Schneider Electric Brass Thermowell (Part No. 9121041000) is a PN16-rated 100mm brass immersion sleeve designed for longer probe sensors in larger-bore hydronic piping systems. This professional-grade component enables safe in-service sensor replacement without requiring system depressurization. Product Specifications Part Number 9121041000 Material Brass Pressure Rating PN16 (16 bar) Insertion Length 100 mm Thread
Schneider Duct Humidity Temp Sensor 4-20mA 10K Ohm Type3 HD5XMSTH New
Schneider Duct Humidity Temp Sensor 4-20mA 10K Ohm Type3 HD5XMSTH New The Schneider Electric Duct Humidity and Temperature Sensor (Part No. HD5XMSTH) delivers simultaneous 4-20mA humidity output (±5% accuracy) and 10K Ohm Type 3 NTC temperature resistance — designed for BAS controllers using Type 3 curve inputs in commercial HVAC duct monitoring. Key Specifications Part Number: HD5XMSTH Humidity Output: 4-20mA, ±5% RH accuracy (0-100% RH) Temperature Output: 10K Ohm NTC, Type